adding counter PZA-A-B Design structure=mechanical sequence counter with pneumatic drive, Type of reset=Pushbutton or pneumatic signal, Display=6-place, Release pressure, drive unit=0,2 ± 0,1 bar, Release pressure, return=0,15 ± 0,1 bar Design structure mechanical sequence counter with pneumatic drive Type of reset Pushbutton or pneumatic signal Display 6-place Release pressure, drive unit 0,2 ± 0,1 bar Release pressure, return 0,15 ± 0,1 bar Response pressure, drive unit 0,6 ± 0,2 bar Response pressure, return 0,6 ± 0,2 bar Operating pressure 2 ... 8 bar Minimum reset pressure 2 bar Minimum pulse length, drive unit 10 ms Minimum pulse length, return 180 ms Minimum pause period, drive unit 15 ms Minimum pause period, return 50 ms