Type code VPEV Conforms to standard EN 60947-5-1 Symbol 991471 Certification CCC CE marking (see declaration of conformity) As per EU low voltage directive Explosion prevention and protection Observe the information on the certificateZone 1 (ATEX)Zone 22 (ATEX)Zone 21 (ATEX)Zone 2 (ATEX) Note on materials RoHS-compliant Measured variable Relative pressure Method of measurement Pneumatic/electric pressure transducer Pressure measuring range -1 bar ... 1.6 bar Operating pressure -1 bar ... 1.6 bar Operating medium Compressed air as per ISO 8573-1:2010 [7:4:4] Information on operating and pilot media Operation with oil lubrication possible (required for further use) Temperature of medium -20 °C ... 80 °C Ambient temperature -20 °C ... 80 °C Switching element function Changeover switch Max. switching frequency 3 Hz Max. switching output voltage AC 250 V Max. switching output voltage DC 125 V Max. output current 5000 mA Minimum load current 10 mA at 10 V100 mA at 5V1 mA at 24 V Utilization category for inductive load AC-14DC-13 Utilization category for ohmic load DC-12AC-12 Type of mounting With through-hole Mounting position Any Pneumatic connection G1/8 Product weight 240 g Housing material Wrought aluminum alloy Switching contact material Silver Switching status indication LED yellow Threshold value setting range -0.95 bar ... -0.2 bar Threshold value setting values after modification 0.16 bar ... 1.6 bar Degree of protection IP65 Corrosion resistance class (CRC) 2 - Moderate corrosion stress