DIGITAL MULTIMETER - Full Function General Purpose • Rotary Range Switch Battery, Test Leads and Operating Instructions Included SPECIFICATIONS: • Diode Test • 0.7% Basic DC Accuracy • 3 1/2 Digit LCD, 0.5” H • 10A DC • 10MΩ Input Impedance, DC • Overload Protection • Pocket Size DC Voltage Range Resolution Accuracy 200mV 0.1mV ±0.7% of rdg ±4D 2000mV 1mV ±0.7% of rdg ±2D 20V 10mV ±0.7% of rdg ±2D 200V 100mV ±0.7% of rdg ±2D 1000V 1V ±0.7% of rdg ±2D Input Impedance: 10MΩ on all ranges DC Current Range Resolution Accuracy 200µA 0.1µA ± 1% of rdg ± 2D 2000µA 1µA ± 1% of rdg ± 2D 20mA 10µA ± 1% of rdg ± 2D 200mA 100µA ± 1.2% of rdg ± 2D 2000mA 1mA ± 1.5% of rdg ± 2D 10A 10mA ± 1.5% of rdg ± 2D Overload Protection: mA input, 2A/250V fuse; 10A input (unfused) up to 10A for 15 seconds AC Voltage Range Resolution Accuracy 200V 100mV ±1.2% of rdg ±10D 750V 1V ±1.2% of rdg ±10D Overload Protection: 750V rms Frequency Range: 45Hz - 450Hz Resistance Range Resolution Accuracy 200Ω 0.1Ω ±0.7% of rdg ±2D 2000Ω 1Ω ±0.7% of rdg ±2D 20KΩ 10Ω ±0.7% of rdg ±2D 200KΩ 100Ω ±0.7% of rdg ±2D 2000KΩ 1KΩ ±1% of rdg ±2D Diode Test Voltage: 2.8V @ 1mA