Keysight 33522B 30 MHz Trueform Waveform Generator, 2-Channel with Arbitrary CapabilityKey Features At A Glance Trueform architecture delivers 4 Vpp); Pulse: 2.9 ns to 10 µs, 100-ps resolution Square/Pulse Duty Cycle 0.01% to 99.99%, 0.01% resolution Square/Pulse Jitter (rms) (meas) Standard: < 40 ps (1 Hz to 20/30 MHz) Standard: < 1 ps; Opt OCX: < 0.5 ps (10 Hz to 40 MHz) Ramp/Triangle Frequency Range 1 µHz to 200 kHz, 1-µHz resolution 1 µHz to 800 kHz, 1-µHz resolution Ramp/Triangle Ramp Symmetry 0% to 100%, 0.1% resolution Ramp/Triangle Non-linearity (typ) < 0.05% from 5% to 95% of the signal amplitude Gaussian Noise Variable Bandwidth (typ) 1 mHz to 20 MHz or 30 MHz 1 mHz to 60 MHz (VOUT ≤ 10 Vpp); to 80 MHz (VOUT ≤ 8 Vpp); to 120 MHz (VOUT ≤ 4 Vpp) Gaussian Noise Crest Factor (nom) 4.6 4.6 Gaussian Noise Repetition Period > 50 years > 100 years PRBS Bit Rate 1 mbps to 50 Mbps 1 mbps to 100 Mbps (VOUT ≤ 10 Vpp); to 200 Mbps (VOUT ≤ 4 Vpp, 120 MHz only) PRBS Sequence Length 2m-1, m = 7, 9, 11, 15, 20, 23 2m-1, m = 3 to 32 Arbitrary Waveforms Waveform Length 8 Sa to 1 MSa per channel (16 MSa with Opt MEM) 32 Sa to 4 MSa per channel (64 MSa with Opt MEM) Arbitrary Waveforms Sample Rate 20 MHz models: 1 µSa/s to 160 MSa/s; 30 MHz models: 1 µSa/s to 250 MSa/s 80 MHz models: 1 µSa/s to 660 MSa/s; 120 MHz models: 1 µSa/s to 1 GSa/s Arbitrary Waveforms Voltage Resolution 16 bits 14 bits Arbitrary Waveforms Sequence Length 1 to 512 steps Output Connector Front-panel BNC, shell and pin isolated from chassis (± 42 V maximum) Output Output Impedance (nom) 50 Ω Amplitude Range 1 mVpp to 10 Vpp into 50 Ω; 2 mVpp to 20 Vpp into open circuit, 4-digit resolution Amplitude Units Vpp, Vrms, or dBm Amplitude Accuracy at 1 kHz (spec) ±(1% of setting in Vpp) ± (1 mVpp) DC Offset Range ±(5 VDC - Peak AC) into 50 Ω; ±(10 VDC - Peak AC) into open circuit DC Offset Accuracy (spec) ±(1% of Offset setting) ± (0.25% of amplitude in Vpp) ± (2 mV) Frequency Accuracy Standard Reference ±(1 ppm of setting + 15 pHz), 1 year, 23 °C ± 5 °C; ±(2 ppm), 1 year, 0 to 55 °C Frequency Accuracy Option OCX ±(0.1 ppm of setting + 15 pHz), 1 year, 0 °C to 55 °C Two-Channel Channel-to-Channel Skew (typ) < 200 ps Two-Channel Crosstalk (typ) < −85 dB Important: Requires Option OCX (oven-controlled crystal timebase) for ±0.1 ppm/year frequency accuracy; Option OCX must be returned to Keysight for installation and calibration. Option MEM (extended arbitrary memory) is only available on arbitrary-capable models (33511B/12B/21B/22B and 33611A/12A/21A/22A).Important: A 1-channel generator cannot be upgraded to a 2-channel generator.Important: GPIB option is included as standard for 33500B Series.Important: The high stability timebase option upgrade (33500U-OCX / 33600U-OCX) must be returned to Keysight for installation and calibration.Important: Option IQP (IQ Player) is included as standard in 33512B/22B and 33612A/22A models.Important: Option MEM is only available on models with arbitrary waveform capability (33511B/12B/21B/22B and 33611A/12A/21A/22A).Recommended pairing: the rear-panel External Frequency Reference Input accepts 10 MHz at 200 mVpp to 5 Vpp, enabling fan-out of up to four Keysight Trueform waveform generators from a single reference for synchronized multi-instrument bench setups.Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.