analogue module CPX-4AE-P-D10 Dimensions W x L x H=(* (including interlinking block), * 50 mm x 107 mm x 55 mm), No. of inputs=4, Diagnosis=(* - Limit value violation per channel, * - Parameterisation error, * - Sensor limit per channel), Parameters configuring=(* - Diagnosis delay per channel, * - Hysteresis per module, * - Unit of measurement, * - Measured value smoothing per channel, * - Diagnosis limit monitoring per channel, * - Diagnostics sensor limit per channel, * - Relative/differential pressure measurement), Measured variable=4x relative pressure/2x differential pressure Dimensions W x L x H (including interlinking block)50 mm x 107 mm x 55 mm No. of inputs 4 Diagnosis '- Limit value violation per channel- Parameterisation error- Sensor limit per channel Parameters configuring '- Diagnosis delay per channel- Hysteresis per module- Unit of measurement- Measured value smoothing per channel- Diagnosis limit monitoring per channel- Diagnostics sensor limit per channel- Relative/differential pressure measurement Measured variable 4x relative pressure/2x differential pressure Unit(s) that can be displayed kPambarpsi LED displays '- 1 Group diagnosis Internal cycle time 5 ms Operating voltage range DC 18 ... 30 V Intrinsic current consumption at operating voltage Typically 50 mA Nominal operating voltage DC 24 V Operating medium Compressed air in accordance with ISO8573-1:2010 [7:4:4] Note on operating and pilot medium Lubricated operation possible (subsequently required for further operation)