pneumatic interface VABA-S6-1-X2-D Valve terminal interface=Type 44, VTSA, Diagnosis=- Undervoltage of valves, Max. number of valve positions=(* 16 with bistable valves, * 32 with monostable valves), LED displays=(* - 1 Group diagnosis, * - Channel status on valves), Parameters configuring=(* Failsafe per channel, * Forces per channel, * Idle mode per channel, * Module monitoring) Valve terminal interface Type 44, VTSA Diagnosis '- Undervoltage of valves Max. number of valve positions 16 with bistable valves32 with monostable valves LED displays '- 1 Group diagnosis- Channel status on valves Parameters configuring Failsafe per channelForces per channelIdle mode per channelModule monitoring Protection (short circuit) Internal electronic fuse protection per valve output Operating voltage range DC 21.6 ... 26.4 V Intrinsic current consumption at operating voltage Typically 15 mA (power supply for electronics)Typically 50 mA (load voltage supply for valve) Max. power supply per channel 0,2 A Max. resultant current per module 0.166666666666667 Nominal operating voltage DC 24 V Electrical isolation channel – internal bus Yes, for additional power supply Corrosion resistance classification CRC 0 - No corrosion stress