※Non-cancelable product ◆Product Introduction The UPS is equipped with a long-life battery (expected life of 5 years at an ambient temperature of 20°C), which can handle a wide range of input voltages from 81 V to 124 V AC with voltage compensation by the AVR function. The UPS control unit is wired to the remote control unit and connected to the main UPS with a cable, making it easy to check the operating status under a desk or in a rack or out of sight. Hot-swappable battery replacement is easy even when the UPS is running, and the front panel can be opened and closed for easy battery replacement while the UPS is running. ◆Product Specifications Operation method Line interactive method Housing Stationary type Rated input voltage 81V AC to 124V AC 3V Rated input frequency 50Hz/60Hz, 10% of maximum Input phase Single-phase 2-wire (grounded) Input outlet shape NEMA5-15R Rated output voltage AC100V 5% for士 Rated output frequency 50Hz/60Hz 0.8% for each phase Number of output phases Single-phase 2-wire (with grounding) Output outlet shape 2P15A outlet with single-phase grounding pole Number of output outlets (backup): 4 *Time-differential turn-on/off function (OUTPUT1:2, OUTPUT2:2) Number of output outlets (through): 0 Power consumption(Normal/max) 35W Maximum output capacity(W) 490W Maximum output capacity (VA) 700VA Backup time (at full load) 5 minutes Output voltage at battery operation 100V Output frequency during battery operation 50/60Hz 0.8% for士 Output waveform during battery operation Sine wave with low distortion Switching time to battery: within 4msec Battery type Small sealed lead-acid battery (expected life: 5 years at 20°C ambient temperature) Hot-swappable / Easy maintenance with full access to battery and fan Number of batteries 1 battery Charging time 5 hours or less Power management software (included) None *Simplified management software can be downloaded from the website. Power management software compatible OS Microsoft Windows/UNIX/Linux/Cobalt Surge function Yes (We have confirmed that there are no problems such as damage to the UPS by applying a voltage of 4000V peak 1.2μS (rising edge) x 50μS (falling edge) between the main circuit and ground, and between the main circuit lines (R-S). Safety standard VCCI class A Main unit size (H x W x D) 160 x 140 x 360 mm Main unit weight 14kg Remarks: Battery output voltage: AC100V 5% for professional Asbestos not included RoHS Directive compliant (Battery on board is not subject to RoHS Directive) J-Moss exempted Date of confirmation 2012-06-14