Uses a long-life battery (expected life: 5 years, ambient temperature: 20°C). Supports a wide range of input voltages from AC 81 V to 124 V by performing voltage correction with the AVR function. Protects backup equipment by preventing lightning surges, noise, etc. The operation part of the UPS is made into a wired remote controller and connected to the main UPS with a cable. It is easy to check the operating status under the desk, in the rack, or out of sight. With the hot-swap method, the front panel can be opened and closed even while the UPS is in operation. The battery can be easily replaced even when the UPS is in operation. With RS232C connector and USB connector Driving method Line interactive method Chassis Stationary Rated input voltage AC81V~124V + 3V Rated input frequency 50Hz/60Hz ±10% Number of input phases Single-phase two-wire system (with ground) Input outlet shape NEMA5-15R Rated output voltage AC100V 5% Rated output frequency 50Hz/60Hz ±0.8% Number of output phases Single-phase two-wire system (with ground) Outlet shape 2P15A outlet with single-phase grounding pole Number of output outlets (backup): 6 *Time lag switch on/off function (OUTPUT 1: 4, OUTPUT 2: 2) Number of output outlets (through) 0 Power Consumption (Normal/Maximum) 70W Maximum Output Capacity (W) 1000W Maximum output capacity (VA) 1400VA Backup time (at full load) 5 minutes Output voltage during battery operation 100V Output frequency during battery operation 50/60Hz ± 0.8% Output waveform during battery operation Low distortion sine wave Time to switch to battery Within 4 ms Battery type Compact sealed lead battery (expected life: 5 years, ambient temperature: 20°C) hot-swappable/maintenance is easy with battery and fan full-surface removal Number of batteries one Charging time Within 5 hours Power management software (attached software) None (sold separately) *Simple management software can be downloaded from the Mitsubishi Electric website Power management software compatible OS Sold separately (FREQSHIP) Windows2000/XP/Sever2003/Vista/solaris10/HP-UX/AIX/RedHat Linux/SUSELinux/MiracleLinux/TurboLinux, etc. Surge function Yes (4000V peak 1.2μS (rising) × 50μS (falling) voltage is applied between the main circuit and ground and between the main circuit lines (between R and S), and it has been confirmed that there is no problem such as damage to the UPS. ) Safety standards VCCI class A Body size (H×W×D) 220×170×440mm body weight 26kg Remarks: Battery output voltage: AC100V 5% Asbestos not included RoHS Directive Compliant (built-in battery is not subject to RoHS Directive) J-Moss Not applicable Regulatory Confirmation Date 2012-06-14