[pdf] [/pdf] 8-8-8 ALUMINUM SEU CABLE Allowable Ampacity for 8-8-8 ALUMINUM SEU CABLE at 60°C: 30 Amps Allowable Ampacity for 8-8-8 ALUMINUM SEU CABLE at 75°C: 40 Amps Allowable Ampacity for 8-8-8 ALUMINUM SEU CABLE at 90°C: 45 Amps Applications: 8-8-8 Aluminum SEU cable is primarily used as a service entrance cable for residential applications, supplying power from the utility meter to the main panel. It can also be used for panel feeders in multi-unit dwellings and branch circuits. This cable has a 600V voltage rating and is designed for use in both wet and dry locations with a maximum operating temperature of 90°C. This particular 8-8-8 size is suitable for: Residential service entrance installations where the neutral also serves as a ground. Supplying power from a utility pole to the main breaker panel. Small subpanel feeders in apartments and multi-unit dwellings. Branch circuits where a combined neutral/ground is acceptable per code. Also Known As: 8-8-8 aluminum seu cable, 8-8-8 seu service entrance cable, 8-8-8 seu cable, 8-8-8 seu wire, 8-8-8 600v wire, 8-8-8 600v cable. Standards: Ampacities based on National Electric Code, 2005 edition, section 310-15 60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors 70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge 90°C wet or dry locations For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service conductors that supply the total load UL 44, 854 Federal Specification J-C - 30B Construction Conductors: The "8-8-8" designation means this SEU cable contains three conductors, each with an 8 AWG (American Wire Gauge) size: Two phase conductors (hot wires) for carrying current. One neutral conductor, which also serves as the ground conductor as per SEU cable design. The conductors are cabled together with a bare aluminum neutral/ground conductor. A reinforced binder tape holds the assembly together. All conductors are made of compact stranded 8000 series aluminum, which is lightweight, corrosion-resistant, and highly conductive. Insulation: Each insulated conductor is coated with XHHW-2 cross-linked polyethylene (XLPE) insulation, which provides: High heat resistance (rated up to 90°C). Moisture resistance for wet and dry locations. Durability against mechanical stress and chemical exposure. Jacket: The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket. Specifications: Insulated Cond(s) Size AWG: 8 Bare Conductor Size AWG: 8 Nominal O.D. Inches: 0.407 Approx. Weight lb/1000FT: 210 lbs Ampacity at 90°C: 45 Amps Ampacity in dwelling: N/A Compatible with Manufacturer Priority Wire & Cable : 8-02ALUMG-SEU Southwire : 13085601