{ "@context": "https://schema.org", "@type": "Product", "name": "2 mL Amber Glass HPLC Autosampler Vials", "sku": "HPLC-112207", "material": "Borosilicate Glass", "description": "2 mL amber glass screw thread HPLC autosampler vials with large opening and step vial design for chromatography applications.", "category": "Laboratory Consumable" } Description In modern HPLC and GC laboratory workflows, automated sample processing places increasing demands on vial consistency, injection stability, and system reliability. Variations in vial geometry, poor needle access, or inconsistent insert positioning can introduce avoidable interruptions in autosampler operation and reduce overall analytical efficiency. High-throughput chromatography systems rely on stable and repeatable sample handling to maintain consistent injection performance across long analytical sequences. Issues such as needle stress during repetitive sampling, sample loss from poor vial fit, and variability in limited-volume handling can directly impact workflow continuity and data consistency. This 2 mL Amber Glass HPLC Autosampler Vial (12×32 mm Screw Thread) is designed to support routine chromatographic sample handling in automated environments where operational stability, sample protection, and consistent injection performance are required. The amber glass format supports light-sensitive sample handling, while the vial geometry is optimized for standard autosampler compatibility and reproducible laboratory workflows. Specification SKU HPLC-112207 Description Amber Glass Screw Thread Vials, HPLC Autosampler Vials Size 12*32mm with a 9mm diameter Height 32mm Width 12mm Cap Size 12mm Capacity 2ml Color Amber Material Borosilicate Glass Graduations Yes Glass Properties Acid-resistant, alkali-resistant, and high-temperature resistant Temperature Resistance -60°C to 200°C Marking Spot Yes Volume (Working) 1.8ml Closure Type Screw Quantity 100/PK Base Style Flat Bottom Features 2 mL amber glass HPLC autosampler vials for chromatography workflows 12×32 mm standard screw thread vial format for automated injection systems Large opening design improves needle access and reduces breakage risk Step vial structure improves insert centering accuracy in vial neck Borosilicate glass material provides chemical and thermal resistance Graduated marking spot supports sample tracking and identification Available silanized option for reduced adsorption in sensitive assays Applications HPLC (High Performance Liquid Chromatography) analysis GC and GC autosampler injection workflows LC-MS sample preparation and analysis Pharmaceutical quality control (QC) testing Environmental analytical chemistry testing Biochemical and metabolite profiling High-throughput autosampler sample screening Autosampler Compatibility Waters 717Plus Waters Acquity Waters CapLC Waters WISP Shimadzu AOC14/1400 Shimadzu AOC-20 Shimadzu AOC88/9 Shimadzu AOC-5000 Shimadzu LC 2010 Shimadzu SIL-HT/10ADVP Thermo Fisher Scientific / DIONEX A-200s/AS 150/800/8000 Thermo Fisher Scientific / DIONEX AS 3000/TRACE GC Thermo Fisher Scientific / DIONEX ASI-100 Thermo Fisher Scientific / DIONEX SURVEYOR LC Thermo Fisher Scientific / DIONEX TriPlus Thermo Fisher Scientific / DIONEX WPS-3000RS Thermo Fisher Scientific / DIONEX WPS-3000SL Techcomp / Varian 8034/8035/8100/8200 Techcomp / Varian 9095/9100 Techcomp / Varian CP-84100 Perkinelmer Autosystem GC/XL/AS-2000 Perkinelmer Claru 500/600 Perkinelmer Integral 4000 Perkinelmer ISS-100/200 CTC Analytics Combipal Agilent 1050 Agilent 1090 Agilent 1100 Agilent 1200 Agilent 1260 G1329B Agilent 1290 Agilent 79855(A) Agilent CTC HTS+HTC PAL Agilent 5880 Agilent 5890 Agilent 6850 Agilent 6890 Agilent 7673A Agilent 7683A Agilent 7820A Agilent 790AA Agilent 7890B Agilent CTC GC PAL Frequently Asked Questions What are these HPLC autosampler vials designed for? These 2 mL amber glass vials are designed for HPLC autosampler use, including sample storage and injection in chromatography workflows. What is the benefit of the large opening design? The large opening design provides a 40% larger target area, as described in the product specification, and is designed to eliminate broken needles due to the increased target area. What materials are these autosampler vials made of? The vials are made of borosilicate glass and are available in amber color. What is the step vial design used for? The step vial design precisely centers a limited volume insert in the neck of the vial. Are marking and graduation features available on these vials? Yes. The vials are available with a graduated marking spot and include graduations as specified in the product details. Are these vials available in different material options? Yes. The product description indicates that vials are available in clear or amber borosilicate glass. What closure type is used for these vials? The closure type for these vials is screw thread. What is the packaging quantity of these vials? The packaging quantity is 100 per pack (100/PK). What is the compatibility information for these autosampler vials? The vials are compatible with the autosampler systems listed in the product compatibility section, including Waters, Shimadzu, Thermo Fisher Scientific / DIONEX, Agilent, PerkinElmer, CTC Analytics, and Techcomp / Varian systems as provided in the product details.