Compressor Controller Model C
Nobody notices compressed air until it stops. Then everyone asks why. Compressor rooms often run two or more compressors in parallel, each with its own pressure switch. Each switch reacts to the same pressure drop alone. One unit takes most of the run hours and wears out first. At peak demand, pressure sags while a spare unit stands idle. A failed unit goes unnoticed until the pressure falls. Service on one unit stops the air. Maintenance follows the calendar instead of run hours. The Compressor Controller Model C runs those compressors as one cluster. What it does Service a compressor while the air stays on. A service day or a failed unit no longer means an air outage you have to explain. When one compressor stops for service or fails, the others continue to supply the required airflow. The lead role moves between controllers, so a unit leaves or rejoins the cluster without a stop. Know about a fault before anyone asks. When something fails, the Model C names the fault, so the repair starts with a cause, not a search. It detects pipe and tank ruptures, high and low temperature, and run times past the set limit. It flags a broken wire or missing pressure sensor, over-pressure, inconsistent readings and, after a restart, a power loss mid-cycle. Alarms reach the people who can act. With the signalling package, your building system knows the air status, so nobody walks to the compressor room to check. Four dry-contact outputs report Operational, Warning, Alarm and Maintenance status, and four inputs accept HALT and option signals. A Cluster Gate shows the same alert on its dashboard over WiFi. More air when demand peaks. The spare units you already paid for add capacity at peak demand instead of standing idle. If pressure keeps falling, the Model C starts another compressor on the network. On a C2, a menu setting allows both heads to run at the same time during high demand. One compressor no longer wears out first. Wear spreads across every compressor, so service intervals stay predictable. The Model C starts the unit with the lowest runtime first, so run hours spread across the cluster. On a C2, it alternates compressors A and B when their temperature or runtime difference passes a set limit. Service what needs it, when it needs it. You plan service from the runtime each controller counts since the last service, not from the calendar. Each controller raises a maintenance-due alert. It logs run hours, on/off cycles, over-run and over-temperature events, temperature extremes, and drain and vent cycles per compressor. Drained, vented and cooled without a reminder. The Model C drains, vents and cools every compressor on its own. It does these jobs better than a timer or a mechanical switch. A timer drains on a fixed schedule, and a switch reacts only after the pressure passes its limit. The Model C drains the tank automatically when the tank holds moisture. It opens the vent valve as part of each compressor cycle. It runs the cooling fan from measured temperature, not on a timer or by hand. The fan starts when the pump crankcase is 4 °C above its starting temperature. It runs until the crankcase is below 60 °C (140 °F). Drives and manages your VFD compressors. The Model C is compatible with variable-frequency drives. The VFD options run a drive on each motor and actively manage the compressor speed. Each motor needs its own drive. Check the utility rebates in your area. What it is The Model C is a compressor controller for industrial and commercial compressed-air systems, where a reliable air supply matters most. C1 controls one compressor. C2 controls a duplex compressor with two compressor heads that feed one tank. A menu setting allows both heads to run at the same time during high demand. Fits the compressors you already run. The Model C replaces the pressure switch on reciprocating compressors from 2 HP. It suits single, duplex and multi-stage units. It drives the motor through a starter, SSR or VFD, existing or new. Keep a redundant control device and the safety valves. Order the Model C as a controller, a Pre-Wire kit, or a complete system. A Cluster Gate model, CG1 or CG2, has the WiFi gate of the cluster built in. Easy to set up. No programming. If you can use a remote control, you can configure the Model C. It starts from factory settings. You adjust them through the menu with the included remote. A 20×4 OLED display shows status and readings. The built-in SD card saves and loads settings and logs. A Cluster Gate adds a web interface for the cluster. How the cluster links Every Model C includes COMPONET, a bus that links the controllers. One COMPONET cluster holds up to 16 C1 or C2 controllers on CAT5 or CAT6 cable, up to 1000 ft. With a Cluster Gate in each cluster, a site can run any number of clusters. Every Model C also includes the Compressor-City link for clusters that include Model R controllers. It links up to 8 units on one Compressor-City network for load sharing, logging and monitoring. The Cluster Gate sets up and controls the cluster through a web interface and logs it over WiFi. A cluster can hold any number of Cluster Gates. One is active and links to the remote server. The others serve as backup or repeaters. A flow sensor is optional. Installation and setup Plan the Model C as a professional installation on your air distribution system. The controller runs on 12 V DC. It connects through three edge connectors and back-panel connections. Digital 1-Wire sensors measure pump and motor temperature, plus room temperature and humidity. A digital 2-wire sensor reads system pressure. Analog-output pressure sensors and a pump RPM sensor are options. Settings arrive factory programmed. You adjust most parameters with the remote at the unit. A Cluster Gate adds a web interface for the same settings. Settings also load from the built-in SD card. Select °C or °F in the menu. Configurations and options Every basic unit (CC1.00000 or CC2.00000) includes these features: Compressor, vent and drain valve control Compressor fan and enclosure fan control Pump and motor temperature probes IR remote control COMPONET link Compressor-City link and HALT input Buzzer and automatic display brightness Built-in SD card for setup and basic logging In each order code, x is 1 for the C1 or 2 for the C2. Each option sets its own digit, so one code can combine several options. Order code Option CCx.30000 Advanced logging: expanded parameters, logged every minute. You receive a coded SD card and setup instructions. CCx.01000 Option relay: you select its function in the menu. Choices: compressor heating, evaporative bilge collector, second-stage cooling fan, or custom functions 1 to 4. CCx.00100 Basic VFD control: 4 digital control outputs and 4 VFD status inputs. Needs one VFD per motor. You receive a coded SD card, a female connector and wiring instructions. CCx.00200 Advanced VFD control: basic VFD control plus PWM speed control and RPM measurement. Needs one VFD per motor. You receive a coded SD card, a female connector and wiring instructions. A C1 gets one NJK-5002C Hall-effect speed sensor with a 1 ft lead, a C2 gets two. CCx.00010 Signalling package: 4 isolated outputs and 4 isolated inputs for site automation. You receive a coded SD card, a female connector and wiring instructions. CGy.00000 Cluster Gate: a C1 (y = 1) or C2 (y = 2) with the WiFi gate of the cluster. A cluster can hold any number. One is active and links to the remote server. The others serve as backup or repeaters. It takes the same option digits. Ordering examples: CC1.00010 is a C1 with the signalling package. CC2.00210 is a C2 with advanced VFD control and the signalling package. CC2.31210 is a C2 with every option. CG1.30000 is a C1 Cluster Gate with advanced logging. What we need to size your cluster SAM Controllers sizes each cluster to the site. Have these answers ready when you join the waitlist. Total air demand in CFM, with the maximum and minimum demand Output of one compressor at peak performance, in CFM Peak-performance temperature of each compressor Minimum and maximum pump operating temperature Maximum motor operating temperature Minimum acceptable system pressure and maximum system pressure Confirmation that your electrical supply can run every compressor at the same time Build yours and reserve. SAM Controllers contacts waitlist members first when units are available. Specifications The right controller for each compressor. C1 controls a single compressor, and C2 controls a duplex compressor. Both fit reciprocating compressors from 2 HP: single, duplex and multi-stage. A display that adjusts to the room. Nobody changes the screen brightness by hand when the room light changes. An ambient light sensor sets the brightness of the 20×4 OLED display. Temperature problems show up as readings, not surprises. Digital probes read the pump and motor: −40 to +125 °C, ±1 °C. A room sensor reads 0–50 °C, ±1 °C, and 20–90 % RH, ±1 % RH. Sensors chosen for the site, not a fixed kit. A digital sensor reads pressure: 0–160 PSI, ±1 %. It fits a 1/8 or 1/4 NPT port and has a 6 ft cable. Analog-output pressure sensors and a pump RPM sensor are options. The Cluster Gate accepts an optional air or liquid flow sensor. Relays for valves, fans and starters. The normally open output relays switch up to 5 A at 250 V AC or 3 A at 24 V DC. Use a starter, SSR or VFD for the motor. Status your building system can read. Nobody walks to the compressor room to learn the state of the air. The optional signalling package adds 4 dry-contact outputs and 4 inputs, with optical contacts as an option. Outputs report Operational, Warning, Alarm and Maintenance, and inputs accept HALT and Option 1 to 4. Room to grow from one cluster to a whole site. COMPONET is standard and holds up to 16 C1 or C2 controllers per cluster. The bus runs on RJ45, CAT5 or CAT6, up to 1000 ft, terminated at both ends. With a Cluster Gate in each cluster, a site runs any number of clusters. Clusters that include Model R controllers link over Compressor-City, up to 8 units per network. Working settings from the first power-up. Setup starts from factory settings, not a blank unit. You adjust them through the menu with the remote, or through the web interface of a Cluster Gate. The built-in SD card saves and loads settings and logs, up to 16 GB. Select °C or °F in the menu. Speed control for VFD compressors. The VFD option gives active control with speed control on each drive. 12 V DC power and edge-connector wiring. The controller runs on 12 V DC, 15 W maximum. The included power supply takes 110–277 V AC. It connects through 3 edge connectors plus back-panel connections. The light gray enclosure measures 7.1 × 5.4 × 2.3 in and is IP21: install it in an enclosure, waterproof outdoors. It operates from −10 to +40 °C, non-condensing, and stores from −20 to +80 °C. A real-time clock is onboard, and the buzzer comes in the kit. FAQ How does the Model C differ from the Model R? The Model R controls one or two compressors. The Model C runs a room of compressors as a cluster. It includes the COMPONET bus as standard and adds options for building status signals and active VFD control. How many compressors can one cluster run? A COMPONET cluster holds up to 16 C1 or C2 controllers. With a Cluster Gate in each cluster, a site can run any number of clusters. A cluster that includes Model R controllers links over Compressor-City, up to 8 units. Does it fit the compressors we already have? Yes, for reciprocating compressors from 2 HP, single, duplex or multi-stage. A pressure sensor replaces the pressure switch, and the controller drives a motor starter, SSR or VFD, existing or new. You add pump and motor probes, an ambient sensor, a vent valve and a drain valve. Keep a redundant control device and the safety valves. Does it work with VFD compressors? Yes. The VFD options drive a variable-frequency drive on each motor with active speed control. Each motor needs its own drive. The advanced VFD option includes a speed sensor. What happens when one compressor fails? The other compressors in the cluster hold the required airflow. The controller shows the fault on its front panel. With the signalling package, it also switches the Alarm output to your building system. Does it replace the safety valves? No. Keep your safety valves. The controller supplements safety components and never replaces them. How do I get one? Build yours and reserve with the form on this page. SAM Controllers contacts waitlist members first when units are available. Have the sizing answers above ready.