Features: 150~1500Vdc 10:1 ultra-wide input range 4KVac I/O high isolation(Reinforced isolation) Protections: Short Circuit / Overload / Over voltage / DC input under voltage / DC input Reverse Polarity Fanless design, fully encapsulated, cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 (DR-type) -40 ~ +80℃ ultra-wide operating temperature (>+50℃ derating) Operating altitude up to 5000 meters 3 years warranty General SpecificationAC input voltage rangeNominal 800Vdc (150~1500Vdc)AC inrush current (max.)Cold start 150A max. @ Vin=800VdcOver-voltage protectionHiccup mode recovers automatically after the fault condition is removedWithstand voltageI/P-O/P:4KVacWorking temperature-40 ~ +80℃ (Refer to "Derating Curve")Safety standardsIEC62109-1(LVD), EAC TP TC 004 approved; Design refer to UL1741(By requested)Dimension (LxWxH)135x70x43.5mm