Keysight E5063A ENA Series Network Analyzer
Keysight E5063A ENA Series Network AnalyzerKey Features At A Glance 2-port S-parameter network analyzer with Type-N female 50 Ω test ports Frequency coverage spanning 100 kHz to 18 GHz across the series, set by frequency option (Option 205 through 2H5) System dynamic range up to 122 dB typical at 10 Hz IF bandwidth GPIB (IEEE-488), LAN 10/100/1000BaseT, USB (USBTMC) device, and 36-pin Handler I/O standard for automated test systems 10.4-inch XGA (1024×768) TFT color LCD with touchscreen Full 2-port calibration supported with Type-N and 3.5 mm mechanical cal kits and ECal modules Selectable IF (system) bandwidth from 10 Hz to 300 kHz The Keysight E5063A is a two-port RF network analyzer in the ENA Series, covering a frequency range from 100 kHz up to a maximum of 18 GHz depending on the installed frequency option. It is built around a 10.4-inch touchscreen front panel with Type-N female 50 Ω test ports, and it characterizes a device under test through both corrected and uncorrected system performance — directivity, source match, load match, reflection tracking, and transmission tracking — across its sweep range.A network analyzer measures how a device under test reflects and transmits RF energy, expressed as S-parameters. The E5063A performs full 2-port calibrated measurements of reflection (S11) and transmission (S21), reporting magnitude and phase, and it also computes group delay from the measured phase change across a specified aperture. These are the core measurements engineers rely on to characterize RF components and networks.Brand HeritageThe test and measurement business that issued this product traces its corporate lineage through Hewlett-Packard, whose test and measurement division was spun out as Agilent Technologies in 1999. That measurement business was subsequently separated to form Keysight Technologies in 2014.Product Core & Specifications Specification Value System Dynamic Range at Test Port (IF Bandwidth = 3 kHz, Specification) 100 kHz to 300 kHz 63 dB 300 kHz to 8.5 MHz 68 dB 8.5 to 100 MHz 91 dB 100 MHz to 4.34 GHz 92 dB 4.34 to 8.5 GHz 81 dB 8.5 to 13 GHz 75 dB 13 to 16 GHz 65 dB 16 to 18 GHz 62 dB System Dynamic Range at Test Port (IF Bandwidth = 10 Hz, Specification) 50 kHz to 100 kHz 88 dB 100 kHz to 300 kHz 88 dB 300 kHz to 8.5 MHz 93 dB 8.5 to 100 MHz 116 dB 100 MHz to 4.34 GHz 117 dB 4.34 to 8.5 GHz 106 dB 8.5 to 13 GHz 100 dB 13 to 16 GHz 90 dB 16 to 18 GHz 87 dB Uncorrected System Performance (Specification, dB) Directivity (100 kHz–300 kHz / 300 kHz–1 MHz / 1–100 MHz / 100 MHz–3 GHz / 3–6 GHz / 6–10 GHz / 10–13 GHz / 13–18 GHz) 10 / 10 / 25 / 25 / 20 / 15 / 10 / 10 dB Source match 20 / 20 / 25 / 25 / 20 / 15 / 15 / 15 dB Load match 7 (typ.) / 11 (typ.) / 14 / 11 / 10 / 7 / 8 (typ.) / 6 (typ.) dB Reflection tracking ± 3.0 / ± 3.0 / ± 1.0 / ± 1.0 / ± 1.0 / ± 1.0 / ± 1.0 / ± 1.0 dB Transmission tracking ± 3.0 / ± 3.0 / ± 1.0 / ± 1.0 / ± 1.0 / ± 1.0 / ± 1.0 / ± 1.0 dB Corrected System Performance — 85032F Calibration Kit (Type-N, 50 Ω, Full 2-port, IFBW=10 Hz; Specification, dB) Directivity (100 kHz–10 MHz / 10 MHz–3 GHz / 3–9 GHz) 49 / 46 / 38 Source match 41 / 40 / 35 Load match 47 / 46 / 36 Reflection tracking ± 0.011 / ± 0.021 / ± 0.054 Transmission tracking ± 0.082 / ± 0.037 / ± 0.128 Corrected System Performance — 85092C ECal Module (Type-N, 50 Ω, Full 2-port, IFBW=10 Hz; Specification, dB) Directivity (300 kHz–10 MHz / 10 MHz–3 GHz / 3–9 GHz) 45 / 52 / 45 Source match 36 / 44 / 36 Load match 36 / 45 / 38 Reflection tracking ± 0.10 / ± 0.04 / ± 0.07 Transmission tracking ± 0.153 / ± 0.052 / ± 0.17 Corrected System Performance — 85033E Calibration Kit (3.5 mm, 50 Ω, Full 2-port, IFBW=10 Hz; Specification, dB) Directivity (100 kHz–10 MHz / 10 MHz–3 GHz / 3–9 GHz) 46 / 44 / 38 Source match 43 / 40 / 36 Load match 45 / 44 / 38 Reflection tracking ± 0.006 / ± 0.007 / ± 0.010 Transmission tracking ± 0.077 / ± 0.040 / ± 0.112 Corrected System Performance — 85093C ECal Module (3.5 mm, 50 Ω, Full 2-port, IFBW=10 Hz; Specification, dB) Directivity (300 kHz–10 MHz / 10 MHz–3 GHz / 3–9 GHz) 45 / 52 / 47 Source match 36 / 44 / 34 Load match 36 / 45 / 39 Reflection tracking ± 0.100 / ± 0.040 / ± 0.070 Transmission tracking ± 0.156 / ± 0.047 / ± 0.155 Corrected System Performance — 85052D Calibration Kit (3.5 mm, 50 Ω, Full 2-port, IFBW=10 Hz; Specification, dB) Directivity (100 kHz–10 MHz / 10 MHz–3 GHz / 3–10 GHz / 10–18 GHz) 42 / 38 / 36 / 36 Source match 37 / 31 / 28 / 28 Load match 42 / 38 / 36 / 36 Reflection tracking ± 0.003 / ± 0.004 / ± 0.008 / ± 0.008 Transmission tracking ± 0.136 / ± 0.100 / ± 0.208 / ± 0.328 Corrected System Performance — N4691B ECal Module (3.5 mm, 50 Ω, Full 2-port, IFBW=10 Hz; Specification, dB) Directivity (300 kHz–10 MHz / 10 MHz–3 GHz / 3–10 GHz / 10–18 GHz) 31 / 46 / 48 / 46 Source match 29 / 41 / 45 / 42 Load match 27 / 42 / 42 / 39 Reflection tracking ± 0.110 / ± 0.050 / ± 0.030 / ± 0.040 Transmission tracking ± 0.358 / ± 0.046 / ± 0.062 / ± 0.107 Test Port Output — Frequency Range (by option) Option 205 100 kHz to 500 MHz Option 215 100 kHz to 1.5 GHz Option 235 100 kHz to 3 GHz Option 245 100 kHz to 4.5 GHz Option 265 100 kHz to 6.5 GHz Option 285 100 kHz to 8.5 GHz Option 2D5 100 kHz to 14 GHz Option 2H5 100 kHz to 18 GHz Resolution 1 Hz (100 kHz to 6.5 GHz); 2 Hz (6.5 to 13 GHz); 11 Hz (13 to 18 GHz) Source stability ± 7 ppm (5 to 40 ºC) CW accuracy ± 7 ppm Test Port Output Power Nominal power (preset power) –5 dBm Range, 50 kHz to 100 kHz –20 to –5 dBm Range, 100 kHz to 300 kHz –20 to 0 dBm Range, 300 kHz to 8.5 GHz –15 to –5 dBm Range, 8.5 to 18 GHz –20 to –5 dBm Resolution 0.05 dB Level Accuracy (level flatness; absolute taken at 50 MHz, –5 dBm) At 50 MHz, –5 dBm, absolute ± 0.9 dB 50 kHz to 300 kHz ± 3.7 dB 300 kHz to 1 MHz ± 2.0 dB 1 MHz to 4.34 GHz ± 1.0 dB 4.34 to 8.5 GHz ± 1.6 dB 8.5 to 12 GHz ± 3.6 dB 12 to 18 GHz ± 5.8 dB Level Linearity (relative to –5 dBm) –10 to –5 dBm, 50 kHz to 300 kHz ± 1.6 dB –10 to 0 dBm, 300 kHz to 8.5 GHz ± 1.6 dB –10 to –5 dBm, 8.5 to 18 GHz ± 1.8 dB –20 to –10 dBm, 50 kHz to 8.5 GHz ± 2.7 dB –15 to –10 dBm, 8.5 to 18 GHz ± 2.9 dB Test Port Input Level Maximum input level +6 dBm Damage level +26 dBm or ± 35 VDC Crosstalk 50 kHz to 100 kHz –88 dB 100 kHz to 300 kHz –93 dB 300 kHz to 8.5 MHz –115 dB 8.5 MHz to 4.34 GHz –105 dB 4.34 to 6 GHz –100 dB Important: Test port maximum input level: +6 dBm. Damage level: +26 dBm or ±35 VDC. Important: Line power: a third-wire ground is required. Important: Specified corrected system performance depends on the calibration kit or ECal module used; the datasheet lists technical specifications for the 85032F, 85033E, 85052D calibration kits and the 85092C, 85093C, N4691B ECal modules. For models not listed, download the free uncertainty calculator from www.keysight.com/find/na_calculator.Recommended pairing: calibrate with the Keysight 85032F (Type-N), 85033E or 85052D (3.5 mm) mechanical kits, or the 85092C, 85093C, or N4691B ECal modules specified for this analyzer.About this New unitThis is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
More you might like
Related
Keysight E5063A ENA Series Network Analyzer (Pre-Owned)
Related