GENERAL SPECIFICATIONS Temperature range AECQ100 GRADE1 (-40 to 125˚C) CPU 32 bits, 90MIPS Reverse polarity protection Yes, internal Operating voltage 6-22V, immunity to transients according to ISO 7637 Enclosure IP 60, bespoke CNC machined aluminum Size (mm) and weight(g) 131x112x32.5, 345g Connectors 1 x 39 position connector, 1 x M6 stud for battery connection PC communication CAN (PCAN, ECUMASTER USBCAN) OUTPUTS High current outputs 10 x 25A(cont.), 6 x 15A(cont.) with Overcurrent and overheating protection. Outputs may be paired to increase continuous current capability. Current and voltage is measured for each output Total current output 150A continuous Output current control step 100mA Wipers output Dedicated output with wiper braking feature Monitored 5V, 500mA output for powering external sensors. INPUTS Analog inputs 16 inputs, 10 Bit resolution, 0-5V (protected), with software selectable 10K Ohm pullup and pulldowns CAN Keypads 2 x Ecumaster keypads (4, 8, 12 keys) OTHER Output state indication 16 bicolor LEDs Accelerometer/Gyroscope 3D accelerometer with 3D gyroscope for logging and crash detection Real time clock Yes, super capacitor for backup power (up to 3 days) CAN BUS CAN interface 2 x CAN2B CAN standard 2.0B 125, 250, 500, 1000 kbps Input/output stream User defined with bit masking, up to 48 input messages LOGGING Logging memory: 256 Mbytes ONLY on PMU16DL version (this is the only difference between the two models). All PMU16 data may be sent via CAN and logged by another device LOGGING SPEED Variable, defined per channel, up to 500Hz FUNCTIONS Logical operators AND, OR, NOT, XOR, Toggle, Flash, Pulse Number of functions: 100 Number of operations: 250 Update frequency: 500Hz Special functions: Wipers, blinkers WHAT'S IN THE BOX: PMU16 Device 39 Position connector with terminals Lock nut and protective plastic cap for M6 main power terminal Laminated Pinout Card RECOMMENDED ACCESSORIES USB to CAN Adapter (you may use a Peak PCAN or Kvaser CAN cable, but one of these three USB to CAN interfaces must be used to program the device) CAN Keyboard (mechanical switches may be connected to any of the 16 analog inputs, but CAN keyboards add functionality to the PMU16)