✦ Verified product
Fluke 1662 Multifunction Testers
AUD 2,464.00
Mektronics Australia
Verified independent store
→
Overview A solid, basic installation tester. The Fluke 1662 Multifunction Installation Tester gives you Fluke reliability, simple operation and all the testing power you need for d
ay-in, day-out installation testing. The Fluke 1662 puts more power in your hands by quickly and efficiently testing to all local regulations. Functions Measurement function Voltage & frequency Wiring polarity checker, detects broken N wires Insulation resistance Continuity & resistance Measure motor windings with continuity test Loop & line resistance Prospective earth fault current (PEFC/IK) Prospective short-circuit current (PSC/IK) RCD switching time RCD tripping level (ramp test) Measures trip time & current for RCD type A & AC in one test RCD variable current Automatic RCD test sequence Phase sequence indicator Features On/Off switchable auto-start for RCD & Looptest Self-test Illuminated display Time and date (when used with optional FlukeView software) Includes 6x AA (IEC LR6) cell batteries C1600 hard carrying case Zero adapter Heavy duty mains cord STD standard test lead set C1600 hard carrying case Padded carrying and waist strap Quick reference guide TP165X remote control probe and lead User's manual on CD-ROM Specifications Specifications AC voltage measurement Range 500 V Resolution 0.1 V Accuracy 45 Hz - 66 Hz 0.8% + 3 Input impedance 360 kΩ Overload protection 660 V rms Continuity testing (RLO) Range (autoranging) 20 Ω / 200 Ω / 2000 Ω Resolution 0.01 Ω / 0.1 Ω / 1 Ω Open Circuit Voltage >4 V Insulation resistance measurement (RISO) Accuracy of tTest voltage (at rated test current) +10%, -0% Test voltage 100 V 250 V 500 V 1000 V Insulation resistance range 20 MΩ / 50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ Resolution 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ Test current 1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ Loop and line impedance (ZI) Range 10 Ω / 0.001 Ω / High current mΩ mode Resolution 0.01 Ω / 0.1 Ω / 1 Ω Prospective earth fault current, PSC test Range 1000 A / 10 kA (50 kA) Resolution 1 A / 0.1 kA Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. RCD testing, RCD types tested RCD Type A4, AC ¹, G ², S ³ Notes ¹Responds to AC ²General, no delay ³Time delay 4Responds to pulsed signal 5Responds to smooth DC signal Tripping speed test (ΔT) Current settings ¹ 10-30-100-300-500-1000 mA - VAR 10-30-100 mA Multiplier x ½, x 1 x 5 Measurement range RCD Type G 310 ms 50 ms RCD Type S 510 ms 160 ms Notes ¹1000 mA type AC only 700 mA maximum type A in VAR mode VAR mode not available for type B. RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) Current range 30% to 110% of RCD rated current ¹ Step size 10% of IΔN ² Dwell time Type G 300 ms/step Type S 500 ms/step Measurement accuracy ±5% Specified trip current ranges (EN 61008-1) 50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (≤10 mA) 50% to 200% for Type B ²5% for Type B Notes ¹30% to 150% for Type A IΔN > 10 mA 30% to 210% for Type A IΔN = 10 mA 20% to 210% for Type B Phase Sequence Indication Icon Phase Sequence indicator is active. Specifications Size (L x W x H) 10 x 25 x 12.5 cm Weight (incl. batteries) 1.3 Kg Battery size, quantity Type AA, 6 ea. Sealing IP-40 Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition Overvoltage CAT III / 500V; CAT IV 300V Performance EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition Resources Fluke 1660 Series multifunction installation testers