Overview Fluke 87V identifies complex signal problems fast. The provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high energy, and high altitude locations. A low pass filter supports accurate frequency measurements on VFDs and captures intermittents as fast 250 µS. Use the 87V to measure AC current up to 10 A directly, or use an optional clamp for high current measurements.frequency to 200 kHz, plus % duty cycle, resistance, continuity and diode test. And it includes a built-in thermometer so you can take temperature readings without having to carry a separate instrument, and more. Plus, with its bright, two-level backlit display you’ll be able to see the results better in dim light. Correctly measure pulse-width modulated motor drive signalsThe Fluke 87V takes the guesswork out of drive system troubleshooting. It includes a unique function for accurately measuring noisy at the VFD and at the motor terminals. Special shielding blocks high frequency, high-energy noise generated by large drive systems. Electrical safetyAll the inputs in the 87V are updated to the thirdand CAT III, 1000 V. They are designed to withstand spikes in excess of 8.000 V. Features Rugged, high accuracy industrial multimeter to measure current, voltage and frequency on complex variable frequency drive (VFD) signals Offers true-RMS AC voltage and current for measuring non-linear signals Captures intermittents as short as 250 µS Safety rated CAT III 1000 V, CAT IV 600 V Includes a built-in thermometer and temperature probe Specifications Specifications Voltage DC Maximum voltage 1000 V Accuracy ±(0.05% + 1) Maximum resolution 10 µV Voltage AC Maximum voltage 1000 V Accuracy ±(0.7% + 2) True RMS AC bandwidth 20 kHz with low pass filter; 3 db @ 1 kHz Maximum resolution 0.1 mV Current DC Maximum amps 10 A (20 A for 30 seconds maximum) Amps accuracy ±(0.2% + 2) Maximum resolution 0.01 µA Current AC Maximum amps 10 A (20 A for 30 seconds maximum) Amps accuracy ±(1.0% + 2) True RMS Maximum resolution 0.1 µA Resistance Maximum resistance 50 MΩ Accuracy ±(0.2% + 1) Maximum resolution 0.1 Ω Capacitance Maximum capacitance 9,999 µF accuracy ±(1% + 2) Maximum resolution 0.01 nF Frequency Maximum frequency 200 kHz Accuracy ±(0.005% + 1) Maximum resolution 0.01 Hz Duty cycle Maximum duty cycle 99.9% Accuracy ±(0.2% per khz + 0.1%) Maximum resolution 0.1% Temperature measurement –200.0 °C – 1090 °C–328.0 °F – 1994.0 °Fexcluding probe 80 BK temperature probe –40.0 °C – 260 °C–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater Conductance Maximum conductance 60.00 nS Accuracy ±(1.0% + 10) Maximum resolution 0.01 nS Diode Range 3 V Resolution 1 mV Accuracy ±(2% + 1) Duty cycle range Accuracy Within ±(0.2% per kHz + 0.1%) Environmental Specifications Operating temperature –20 °C to + 55 °C Storage temperature –40 °C to + 60 °C Humidity (without condensation) 0% – 90% (0 °C – 35 °C)0% – 70% (35 °C – 55 °C) Operating Altitude 2000 m Safety Specifications Overvoltage category EN 61010–1 to 1000 V CAT III, 600V CAT IV Agency approvals UL, CSA, TÜV, VDE listed Mechanical and General Specifications Size 201 x 98 x 52 mm (with holster) Weight 355 g624 g – with holster Display Digital 6000 counts updates 4/sec.19,999 counts in high–resolution mode Analog 32 segments, updates 40/sec Frequency 19,999 counts, updates 3/sec at > 10 Hz Warranty Lifetime Battery Life Alkaline ~400 hours typical, without backlight Shock 1 Meter drop per IEC 61010–1:2001 Vibration Per MIL–PRF–28800 for a Class 2 instrument Includes TL75 Test Leads AC175 Alligator Clips Holster 9V Battery (Installed) 80BK Temperature Probe Datasheets 87V Detailed Specification Sheet 8x-to-2x Conversion Guide