GEMORO XRF Gold and Alloy Analyzer
GEMORO XRF Gold and Alloy Analyzer Manufactured in the USA, the GEMORO XRF Analyzer is among the best in its class and an excellent choice for your investment. Designed for accurac y, speed, and ease of use, this advanced analyzer helps professionals quickly determine the composition of precious metals with confidence. The GEMORO XRF is a handheld, portable Energy Dispersive XRF spectrometer built for jewelers, pawnshops, appraisers, precious metal buyers, and manufacturers. This fast and efficient technology allows users to quickly identify and measure each element in jewelry, coins, watches, and more. Lightweight yet rugged, it is engineered for reliable, all-day operation. Key Benefits Fast, accurate metal analysis Portable, handheld design Easy-to-use interface Ideal for jewelry, coins, watches, and precious metals Durable construction for daily professional use Payment Information Payment for this item is accepted via: Wire transfer/E-Check / ACH (please contact us for payment details) Credit card (3% processing fee applies; a secure payment link will be provided once the order is received) Please allow 7–10 business days for processing. For questions or to place an order, please contact us directly. X-ray Fluorescence or XRF is a non-destructive, analytical method used to determine elemental concentrations of various materials on the surface of what is being analyzed. It’s important to recognize that not all XRF analyzers have the same capabilities. The GEMORO XRF determines the percentage of each element, thoroughly measuring an area 1.5mm in diameter while reaching a robust depth of 15-20 microns. Five times the typical depth of gold plating which has a thickness of only 1-3 microns. This state-of-the-art instrument represents a high-tech alternative to a destructive fire assay. Each unit includes two 6-hour long-lasting rechargeable batteries and an AC adapter. Ability to set a passcode access parameter to manage user access. WIFI/Bluetooth/USB connection capabilities allow you to quickly send sample images and test results to your computer for easy filing. This feature-rich unit comes with a protective Pelican Case to ensure it arrives in perfect condition and enables you to carry it into the field. Range of Precious Metal Elements the GEMORO XRF Gold & Alloy Analyzer can measure: Gold (Au) Silver (Ag) Lead (Pb) Nickel (N) Copper (Cu) Zinc (Zn) Iron (Fe) Tungsten (W) Tin (Sn) Rhodium (Rh) Tantalum (Ta) Titanium (Ti) Cadmium (Cd) Does not measure for Aluminum (Al), Magnesium (Mg), or Silicon (Si). Also measures the following elements: Chromium (Cr) Manganese (Mn) Cobolt (Co) Gallium (Ga) Bismuth (Bi) Zirconium (Zr) Molybdenum (Mo) Ruthenium (Ru) Indium (In) Antimony (Sb) Vanadium (V) Selenium (Se) Yttrium (Y) Niobium (Nb) Hafnium (Hf) Rhenium (Re) SPECIFICATIONS Testing Area 1.5mm Diameter Measuring Depth 15-20 Microns Tube Life Expectancy 8,000 Hours or 48,000 Tests Tube Specification 40K V, 200uA Anode for Alloy Detector 7mm2 PiN Diode Detector (active area), 190eV resolution FQHM at 5.95Mn K-Alpha Line Battery Life Includes AC Adapter and 2 Rechargeable Batteries. 6 Hour Battery Life Per Battery Certifications & Compliance CE, RoHS, USFDA, Canada RED Act Product Weight 3.3 Lbs Product Dimensions 7.25 x 10.5 x 4.5 Inches Computer Data Transfer WIFI, Bluetooth, USB Connectivity to Most Devices Calibration Check Very Quick – Internal Shutter is 316 Stainless for Totally Automated Calibration and Energy Scale Validation Environmental Temp. Range 10°F to 130°F at 25% Duty Cycle Security Password Protected Usage (user level) and Internal Settings (admin) XRF Spectrometry Data Method XRF Spectrometry can use either Empirical Methods (calibration curves using standards similar in property to the unknown) or Fundamental Parameters (FP) to arrive at quantitative elemental analysis. The GEMORO XRF Gold and Alloy Analyzeruses the superior Fundamental Parameters because it allows elemental analysis to be performed without standards or calibration curves, which is much more preferred. This enables the analyst to use the system immediately, without having to spend additional time setting up individual calibration curves for the various elements and materials of interest. FP, accompanied by stored libraries of known materials, determines not only the elemental composition of an unknown material quickly and easily, but can identify unknown materials as well. More on How XRF works: XRF works by striking a sample with an X-ray beam from an X-ray tube, causing characteristic X-rays to fluoresce from each element in the sample. A detector measures the energy and intensity (number of X-rays per second at a specific energy) of each X-ray, which is transformed into an elemental concentration using either a non-standard technique such as fundamental parameters or user-generated calibration curves. The presence of an element is identified by the element’s characteristic X-ray emission wavelength or energy. The amount of an element present is quantified by measuring the intensity of that element’s characteristic X-ray emission. The Atomic Level All atoms have a mixed number of electrons. These electrons are arranged in orbitals around the nucleus. Energy Dispersive XRF (EDXRF) typically captures activity in the first three electron orbitals, the K, L, and M lines. These electrons are arranged in orbitals around the nucleus. Energy Dispersive XRF (EDXRF) typically captures activity in the first three electron orbitals, the K, L, and M lines. The primary photons from the X-ray tube have high enough energy that they knock electrons out of the innermost orbitals, creating a vacancy (1). An electron from an outer orbital will move into the newly vacant space at the inner orbital to regain stability within the atom (2). As the electron from the outer orbital moves into the inner orbital, it releases energy in the form of a secondary X-ray photon. This energy release is known as fluorescence. All elements produce fluorescence “characteristic” to themselves. Each element’s fluorescence is unique to itself. X-RAY Sample Material High-energy primary X-ray photons are emitted from an X-ray tube and strike the sample. DETECTOR Sample Material The fluorescent energy is transferred to a detector, where it is absorbed and transferred into an electrical signal and then into a number (digitized). While XRF analyzing technology is very precise, please recognize that this technology measures the elements present on the surface (AKA a “surface test”), and it should not be considered as a substitute for a fire assay of a core sample. PLEASE NOTE: Some states require the user to register this device with your local state departments. This is required by law and is the responsibility of the user/buyer and failure to do this could result in fines/penalties.