Hi-Link DC-DC 5W Isolated Module 24V to 3.3V 1200mA Single Output
Hi-Link HLK-URB2403YMD-5WR3 is a compact isolated DC-DC converter that steps down 24V DC (9-36V wide range) to a stable 3.3V / 1200mA single output at 5W rated power. Featuring gal vanic isolation, -40°C to +85°C industrial temperature range, and built-in short-circuit protection, this SIP module is designed for industrial control systems, automotive electronics, PLC boards, and embedded 3.3V rail applications powered from 24V bus. Specifications Input Voltage (Nominal): 24V DC Input Voltage (Range): 9-36V DC wide range Output Voltage: 3.3V DC (single output) Output Current (max): 1200mA (1.2A) Rated Power: 5W continuous output Efficiency: ≥80% typical at full load Isolation Voltage: 1500V DC (input-to-output galvanic isolation) Output Voltage Accuracy: ±1% at full load Ripple & Noise: ≤50mVp-p (20MHz bandwidth) Load Regulation: ≤±0.5% Line Regulation: ≤±0.5% Short-Circuit Protection: Built-in continuous protection, auto-recovery Overcurrent Protection: Built-in Operating Temperature: -40°C to +85°C Storage Temperature: -55°C to +125°C Cooling Method: Free air convection (no heatsink required) Package / Dimensions: SIP-7 / 25.4 × 25.4 × 11mm (L × W × H) Weight: Approx. 8g Pinout: Fixed SIP-7 footprint — consistent across URB_YMD family for multi-voltage design-in Certifications: CE / RoHS compliant; UL94-V0 PCB material Key Features Wide 9-36V input range — covers 12V, 24V, and industrial DC bus variations 3.3V / 1.2A regulated output — direct power for MCUs, FPGAs, sensors, and logic ICs 5W continuous rated power — sufficient for processor boards and multi-IC modules 1500V DC galvanic isolation — protects downstream circuits from high-voltage transients High efficiency ≥80% — minimal heat, no heatsink or fan needed Low ripple ≤50mVp-p — clean 3.3V rail for noise-sensitive digital circuits -40°C to +85°C operating range — industrial and automotive grade reliability Built-in short-circuit & overcurrent protection — auto-recovery on fault clearance Compact SIP-7 package 25.4×25.4×11mm — standard footprint shared across URB_YMD series Consistent pinout across input/output voltage variants — easy multi-voltage design-in on one PCB Applications Industrial PLC and control board 3.3V rail — power logic from 24V industrial bus Automotive & EV electronics — 24V vehicle bus to 3.3V MCU/sensor supply Embedded system power supply — STM32, ESP32, FPGA core voltage from 24V rail Motor driver control boards — isolated 3.3V logic supply alongside high-voltage drive stage Industrial sensor & transmitter power — 4-20mA loop-powered device supply Robotics and servo systems — isolated logic-level power from 24V servo bus Energy meters and smart grid equipment — measurement circuitry isolated power Railway and transportation electronics — wide-temp, isolated DC-DC for harsh environments Communication equipment — RS-485 / CAN transceiver isolated power supply Medical equipment auxiliary power — isolated low-voltage supply for sensor readout circuits Package Includes 1 × Hi-Link HLK-URB2403YMD-5WR3 DC-DC Power Module (3.3V / 1200mA / 5W) Pin assignments: +Vin / -Vin / NC / +Vout / -Vout / Ctrl / NC (SIP-7 footprint) Datasheet reference: URB2403YMD-5WR3 — part of the HLK-URB 24V-input series External components: Input/output filter capacitors recommended per datasheet for optimal EMC performance FAQ Q: What is the input voltage range for this module?A: The HLK-URB2403YMD-5WR3 accepts 9-36V DC wide range, with 24V nominal. It works reliably across 12V-24V industrial bus variations. Q: What is the output voltage and current?A: Single output: 3.3V DC at up to 1200mA (1.2A), rated 5W continuous. Q: What is the isolation voltage between input and output?A: 1500V DC galvanic isolation — protects the 3.3V output circuit from input-side transients and ground differences. Q: Does this module need a heatsink or external cooling?A: No. At ≥80% efficiency, heat dissipation is minimal and free-air convection is sufficient for normal operating conditions. Q: What is the operating temperature range?A: -40°C to +85°C — industrial and automotive grade, suitable for outdoor enclosures and vehicle electronics. Q: How does the URB (single output) differ from the URA (dual output) variant?A: URB series provides a single regulated output (e.g. 3.3V). URA series provides dual symmetric outputs (e.g. ±12V or ±5V) for analog circuits requiring bipolar supply. Choose URB for digital logic, URA for op-amp and analog front-end circuits. Q: How does the 5W variant compare to the 6W variant (URB2403YMD-6WR3)?A: The 6W variant (1400mA output) provides 17% more current capacity for higher-load designs. The 5W variant (1200mA) covers most MCU and sensor board requirements at lower cost. Q: Can this module be used in 12V systems?A: Yes — the 9-36V input range covers 12V nominal systems. The same module works in both 12V and 24V DC bus environments. Q: What external components are recommended?A: Input-side bulk capacitor (47-100µF) and output-side filter capacitor (100µF ceramic + 10µF electrolytic) per Hi-Link application note for optimal ripple performance. Q: Is this module compatible with other URB_YMD variants?A: Yes — the entire URB_YMD family shares a consistent SIP-7 footprint. You can swap between 3.3V, 5V, 12V, 15V, 24V output variants on the same PCB without layout changes.
More you might like
Related
MTE DC Link Choke DCA001203 4.0mH 12A DC 1000V DC Hipot: 360
Related
MTE DC Link Choke DCA000904 11.5mH 9A DC 1000V DC Hipot: 360
Related
MTE DC Link Choke DCA001203 4.0mH 12A DC 1000V DC Hipot: 360
Related