Cisco IE-3200-8T2S-E Switch
[shortdesc] Network Essentials Switch Managed 8 x 10/100/1000 + 2 x Gigabit SFP DIN rail mountable DC power [/shortdesc] [properties] Properties Cisco IE-3200-8T2S-E Description Ca talyst IE3200 w/ 8 GE Copper and 2 GE SFP, Fixed System, Network Essentials Product Family Cisco Catalyst IE3200 Rugged Series Product Type Ethernet Switch Switches Total Ports 10 10/100/1000 RJ45 Copper Ports 8 100/1000 SFP Ports 2 Software License (Default) Network Essentials PoE/PoE (+) budget N/A Software Features Network EssentialsLicense (Perpetual) Features Layer 2 Switching IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP, VTPv2, VTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST+, MSTP, and RSTP Multicast IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier Management WebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FSPAN, Express Setup, NETCONF, RESTCONF Security Port security, 802.1X, DHCP Snooping, Dynamic ARP Inspection (DAI), IP Source Guard, SSH/SNMPv3, TACACS+/RADIUS, (SKU-dependent) MACsec-128, FIPS 140-2 Quality of Service (QoS) 802.1p, DSCP, Auto-QoS, policing and shaping, priority queuing (8 egress queues) IPv6 IPv6 host support, HTTP over IPv6, SNMP over IPv6 Layer 3 Routing IPv4 static routing, Inter-VLAN routing Utility MODBUS TCP/IP Industrial Ethernet EtherNet/IP (CIP), PROFINET, IEEE 1588 PTP v2 (default and power) Redundancy Resilient Ethernet Protocol (REP) ring, PROFINET Media Redundancy Protocol (MRP), REP Preferred, Fast REP Automation YANG, NETCONF, RESTCONF Dimensions (HxWxD) Inches 6 in. x 3.6 in. x 5.3 in.15.2 cm x 9.1 cm x 13.5 cm Weight 3.8 lbs (1.7 kg) Mounting DIN Rail [/properties][specifications] Specifications IE-3200-8T2S-E DRAM 2 GB Flash Memory 1.5 GB Hardware PoE power budget Not applicable Removable storage USB (Optional), SD card (Optional) Alarms 2 alarms in, 1 alarm out Console ports 1 RS-232 (via RJ-45), 1 USB Mini Type B Power inputs Dual DC power inputs Number of Queues 8 Forwarding Rate Line rate for all ports and all packet sizes Unicast MAC addresses 8000 Jumbo Frames 8996 bytes No. of VLANs 256 Internet Group Management Protocol (IGMP) Multicast Groups 1000 Spanning Tree Protocol (STP) instances 128 Access Control Entries (PACL/VACL/RACL) 3000 SD card capacity (Optional) 4 GB, 16 GB Input Voltage Range Redundant DC input voltage: 9.6 to 60 VDC Maximum Input Current 2.4A Power Consumption 23W Operating Temperature -40°C to +70°C (40 LFM vented enclosure)-40°C to +60°C (sealed enclosure)-34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure)+85°C (type tested for 16 hours) Storage Temperature -40°C to +85°C Operating Altitude Up to 15,000 feet Storage Altitude 15,000 feet Mean Time Between Failures (MTBF) 641,150 Industrial Automation Control System IEC 62443-4-1IEC 62443-4-2 Electromagnetic emissions FCC 47 CFR Part 15 subpart B Class AEN 55032/CISPR 32 Class AVCCI Class AAS/NZS CISPR 32 Class ACISPR 11 Class AICES 003 Class ACNS 13438 Class AKN 32 Class AEN 300 386 Electromagnetic immunity CISPR 24EN 55024KN 35EN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV)EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP)EN 61000-4-4 Electromagnetic Fast Transients (4kV)EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP)EN 61000-4-6 Conducted RF (10Vrms UTP)EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m)EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec)EN 61000-4-17 Ripple Immunity DC Power (10%)EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz)EN-61000-4-29 DC Voltage Dips and interruptions Industry standards EN 61000-6-2 Industrial ImmunityEN 61000-6-4 Industrial EmissionsEN 61000-6-1 Light Industrial ImmunityEN 61326-1 Measurement, Control and Laboratory EquipmentIEEE 1613 Electric Power Stations Communications NetworkingEN/IEC 61850-3 Electric Substations Communications NetworkingEN50121-4 Railway Signaling and Telecommunications ApparatusEN50155 Railway applications - Rolling stockODVA Industrial EtherNet/IPNEMA TS 2-2016IP30 Marine I DNC Certification according to class guideline DNV-CG-0339Additional Standards:IEC 60945, IACS UR E10 Safety standards and certifications Information technology equipment:UL/CSA 60950-1, IEC 60950-1 CB with all country deviationsUL/CSA 62368-1, IEC 62368-1 CB with all country deviationsIndustrial floor (control equipment):UL/CSA 61010-2-201CB report and certificate to IEC/EN 61010-2-201Hazardous locations:UL121201 (Class I, Div 2, groups A-D)CSA 213 (Class I, Div 2, groups A-D)UL/CSA 60079-0, -15 (Class I, Zone 2, Gc/IIC)IEC 60079-0, -15 IECEx test report (Class I, Zone 2, Gc/IIC)EN 60079-0, -15 ATEX certificate (Class I, Zone 2, Gc/IIC) Cabinet enclosure required Humidity Relative humidity of 5% to 95% non-condensingIEC 60068-2-78IEC 60068-2-30 Shock and vibration IEC 60068-2-27 (operational shock, 50G, 3ms, half sine)IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal)MIL-STD-810, Method 514.4IEC 60068-2-6 (vibration-sinusoidal, 5Hz-150Hz) Corrosion IEC 60068-2-52 (salt fog)IEC 60068-2-60 (flowing mixed gas) [/specifications][accesories] Accessories and License Upgrade PIDs SD-IE-4GB= Industrial Ethernet (IE) 4-GB SD memory card for IE SD-IE-16GB= Industrial Ethernet (IE) 16-GB SD memory card for IE STK-RACK-DINRAIL= 19" DIN Rail mount kit IE3200-DNA-E Cisco Catalyst Center Essentials license for IE3200 Series IE3200-DNA-E-3Y IE 3200 Catalyst Center Essentials, 3 Year Term license IE3200-DNA-E-5Y IE 3200 Catalyst Center Essentials, 5 Year Term license IE3200-DNA-E-7Y IE 3200 Catalyst Center Essentials, 7 Year Term license LIC-MRP-MGR-XE= MRP Ring Manager License LIC-MRP-CLIENT-XE= MRP Ring Client License IE 3200 Series Power Supplies PWR-IE50W-AC 50W AC Power Supply PWR-IE50W-AC-IEC= 50W AC-IEC Power Supply PWR-IE50W-AC-L 50W AC-L Power Supply PWR-IE65W-PC-AC 65W PC-AC Power Supply PWR-IE65W-PC-DC 65W PC-DC Power Supply PWR-IE170W-PC-AC 170W PC-AC Power Supply PWR-IE170W-PC-DC 170W PC-DC Power Supply PWR-IE240W-PCAC-L 240W PCAC-L Power Supply PWR-IE480W-PCAC-L 480W PCAC-L Power Supply SFPs GLC-FE-100FX-RGD= 100BASE-FX Rugged SFP for Fast Ethernet SFP Ports GLC-FE-100LX-RGD 100BASE-LX10 Rugged SFP for Fast Ethernet SFP Ports GLC-FE-100FX= 100BASE-FX SFP for Fast Ethernet SFP Ports GLC-FE-100LX= 100BASE-LX10 SFP for Fast Ethernet SFP Ports GLC-FE-100EX= 100BASE-EX for Fast Ethernet SFP Ports GLC-FE-100ZX= 100BASE-ZX for Fast Ethernet SFP Ports GLC-FE-100BX-D= 100BASE-BX10-D SFP for Fast Ethernet SFP Ports GLC-FE-100BX-U= 100BASE-BX10-U SFP for Fast Ethernet SFP Ports GLC-SX-MM-RGD= 1000BASE-SX short wavelength; rugged GLC-LX-SM-RGD= 1000BASE-LX/LH long wavelength; rugged GLC-ZX-SM-RGD= 1000BASE-ZX extended distance; rugged GLC-BX40-U-I= 1000BASE-BX40-U for 40km Single-Fiber Bidirectional Applications; with DOM GLC-BX40-D-I= 1000BASE-BX40-D for 40km Single-Fiber Bidirectional Applications; with DOM GLC-BX40-DA-I= 1000BASE-BX40-D (Alternative) for 40km Single-Fiber Bidirectional Applications; with DOM GLC-BX80-U-I= 1000BASE-BX80-U for 80km Single-Fiber Bidirectional Applications; with DOM GLC-BX80-D-I= 1000BASE-BX80-D for 80km Single-Fiber Bidirectional Applications; with DOM GLC-SX-MMD= 1000BASE-SX short wavelength; with DOM GLC-LH-SMD= 1000BASE-LX/LH long-wavelength; with DOM GLC-EX-SMD= 1000BASE-EX long-wavelength; with DOM GLC-ZX-SMD= 1000BASE-ZX extended distance; with DOM GLC-BX-D= 1000BASE-BX10-D downstream bidirectional single fiber; with DOM GLC-BX-U= 1000BASE-BX10-U upstream bidirectional single fiber; with DOM GLC-BX-D-I= 1000BASE-BX10-D downstream bidirectional single fiber, (IND) rated, with DOM GLC-BX-U-I= 1000BASE-BX10-U upstream bidirectional single fiber, (IND) rated, with DOM CWDM-SFP-xxxx= (8 freq) Longwave xxxx-nm laser, single mode DWDM-SFP-xxxx= (40 freq) 1000BASE-DWDM SFP SFP-GE-S= Cisco 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength, extended operating temperature range. SFP-GE-L= Cisco 1000BASE-LX/LH SFP transceiver module for MMF and SMF, 1300-nm wavelength, extended operating temperature range. SFP-GE-Z= Cisco 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength, extended operating temperature range. GLC-SX-MM= Cisco 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength, commercial operating temperature range. GLC-LH-SM= Cisco 1000BASE-LX/LH SFP transceiver module for MMF and SMF, 1300-nm wavelength, commercial operating temperature range. GLC-ZX-SM= Cisco 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength, commercial operating temperature range. GLC-TE= 1000BASE-T standard GLC-T-RGD= 1000BASE-T standard [/accesories] Cisco IE-3200-8T2S-E Industrial Ethernet Switch The Cisco IE-3200-8T2S-E is a high-performance industrial Ethernet switch designed to deliver reliable and secure network connectivity in harsh environments. This switch features 8 Gigabit Ethernet ports and 2 SFP slots, making it an ideal solution for connecting critical industrial devices such as IP cameras, sensors, and controllers. The IE-3200-8T2S-E is engineered to operate under extreme conditions, ensuring continuous operation while offering advanced Layer 2 and Layer 3 management features for effective network segmentation, security, and traffic control. Key Features: 8 x Gigabit Ethernet Ports: Provides reliable and high-speed data connectivity for various industrial devices, ensuring stable network communication. 2 x SFP Slots: Offers flexible uplink options with fiber connectivity, enabling high-speed data transfer and network scalability. Ruggedized Design: Built to withstand extreme temperatures, shock, and vibration, making it ideal for challenging industrial environments. Layer 2 and Layer 3 Management: Includes advanced features such as VLANs, QoS, and routing protocols to enhance network control and security. Compact Form Factor: Designed for space-constrained installations, making it suitable for industrial enclosures and cabinets. Technical Overview: Recommended for: Industrial environments requiring robust Ethernet connectivity with advanced management features. Ports: 8 x Gigabit Ethernet ports, 2 x SFP slots. Operating Temperature: Designed to operate in a wide temperature range suitable for harsh industrial applications. Management: Managed through a web interface, CLI, SNMP, and Cisco Catalyst Center for comprehensive network setup and monitoring. Form Factor: Rugged, compact design suitable for space-constrained industrial environments. You can check the related tab for the Cisco IE-3200-8T2S-E datasheet.
More you might like
Related
Cisco IE-3200-8T2S-E
Related
Cisco Catalyst IE-3200-8T2S Rugged Switch
Related
CISCO Catalyst IE-3200-8T2S Rugged Switch
Related