Cisco IE-4000-4GC4GP4G-E Switch
[shortdesc] Switch Managed 8 x combo Gigabit SFP + 4 x 10/100/1000 (PoE+) DIN Rail Mountable PoE+ DC power [/shortdesc] [properties] Properties Cisco IE-4000-4GC4GP4G-E Description IE4000 switch with 4 GE combo, 4 GE PoE+ and 4 GE combo uplink ports Product Family Industrial Ethernet 4000 Product Type Ethernet Switch Switches Total Ports 12 GE combo (SFP or RJ45) uplinks (4G) All models have 4 GE combo uplink ports Additional combo (SFP or RJ45) ports 4 GE RJ45 copper ports (T) - SFP fiber ports (S) - PoE/PoE+ ports (P, GP), Maximum PoE power budget 4 GE, 125W Default software License All models ship with LAN Base feature set Software Features LAN Base License (Default) Features Layer 2 Switching IEEE 802.1, 802.3, 802.3at, 802.3af standard, VTPv2, NTP, UDLD, CDP, LLDP, Unicast Mac filter, Flexlink, Resilient Ethernet Protocol (REP), VTPv3, EtherChannel, Voice VLAN, QinQ tunneling, Industrial macro configuration Layer 2 multicast IGMPv1, v2, v3 Snooping, IGMP filtering, IGMP Querier Managament Fast Boot, Express setup, Web Device Manager, Industrial Network Director (IND), MIB, Smartport, SNMP, syslog, storm control, unicast, multicast, broadcast, SPAN sessions, RSPAN, DHCP server, customized DOM (digital optical management), Embedded Event Manager (EEM), Plug-n-Play Agent, Port-based DHCP Security SCP, SSH, SNMPv3, TACACS+, RADIUS Server/Client, MAC Address Notification, BPDU Guard, Port-Security, Private VLAN, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard, 802.1x, Guest VLAN, MAC Authentication Bypass, 802.1x Multi-Domain Authentication, Storm Control, Trust Boundary, FIPS 140-2, ACT2, Secure boot, Full flexible Netflow Quality of Service (QoS) Ingress Policing, Rate-Limit, Egress Queueing/shaping, AutoQoS, QoS, PROFINET QoS Layer 2 IPv6 IPv6 Host support, HTTP over IPv6, SNMP over IPv6 Layer 3 Routing IPv4 Static Routing Utility Power Profile 2011 and 2017, dying gasp, GOOSE messaging, SCADA protocol classification, MODBUS TCP/IP, utility SmartPort macro, BFD, Ethernet OAM, IEEE 802.3ah, CFM (IEEE 802.1ag) Industrial Ethernet CIP Ethernet/IP, Profinet v2, IEEE 1588 PTP v2, NTP to PTP translation, CIP Time Sync Redundancy Redundancy Ethernet Protocol ring (REP)Parallel Redundancy Protocol (PRP)Media Redundancy Protocol (MRP) ring, MRP Auto Manager (MAM)High Availability Seamless Redundancy (HSR), PTP over HSRHSR-PRP (Dual RedBox mode)HSR-HSR (Quadbox) Industrial Management Layer 2 switching with 1:1 static Network Address Translation (NAT) Dimensions (HxWxD) Inches 6.12 x 6.12 x 5.09 in. (155.4 x 155.4 x 129.2 mm) Weight 6.35 pounds (2.88 kg) [/properties][specifications] Specifications IE-4000-4GC4GP4G-E DRAM 1 GB Flash Memory 128 MB Hardware PoE power budget Not applicable Removable storage 1-GB removable SD flash memory card (Included)Mini-USB connector Alarms Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay Console ports RJ-45 connector Power inputs Dual DC power inputs Number of Queues 4 egress Forwarding Rate Line rate for all ports and all packet sizes Unicast MAC addresses 16,000 Jumbo Frames 8996 bytes No. of VLANs 1,000 Internet Group Managament Protocol (IGMP) Multicast Groups 1000 IPv4 MAC security ACEs 1,000 with default TCAM Template NAT translation Bidirectional, 128 unique subnet NAT translation entries, which can expand to tens of thousands of translated entries if designed properly Input Voltage Range Redundant DC input voltage: nominal 9.6 to 60VDC Maximum Input Current 4.3A Power Consumption 40W Operating Temperature Operating Temperature: -40C to +75C-40C to +70C (Vented Enclosure Operating)-40C to +60C (Sealed Enclosure Operating)-34C to +75C (Fan or Blower equipped Enclosure Operating)EN 60068-2-1EN 60068-2-2EN 61163 Storage Temperature -40 C to +85 C Operating Altitude Up to 15,000 feet Storage Altitude 15,000 feet Mean Time Between Failures (MTBF) 550, 940 Hours Industrial Automation ControlSystem IEC 62443-4-1IEC 62443-4-2 Electromagnetic emissions FCC 47 CFR Part 15 Class AEN 55022A Class AEN 300 386VCCI Class AAS/NZS CISPR 22 Class ACISPR 11 Class ACISPR 22 Class AICES 003 Class ACNS13438 Class AKN22 Electromagnetic immunity EN55024CISPR 24AS/NZS CISPR 24KN24EN 61000-4-2 Electro Static DischargeEN 61000-4-3 Radiated RFEN 61000-4-4 Electromagnetic Fast TransientsEN 61000-4-5 SurgeEN 61000-4-6 Conducted RFEN 61000-4-8 Power Frequency Magnetic FieldEN 61000-4-9 Pulse Magnetic FieldEN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m)EN 61000-4-11 AC Power VoltageEN 61000-4-18 Damped Oscillatory WaveEN-61000-4-29 DC Voltage Dips Industry standards EN 61000-6-1 Light Industrial EN 61000-6-2 IndustrialEN 61000-6-4 IndustrialEN 61326 Industrial ControlEN 61131-2 Programmable ControllersSubstation KEMA (IEEE 1613, IEC 61850-3)Marine DNV GL (Ships; High speed and light craft)*NEMA TS-2 (EMC, environmental, mechanical)IEEE 1613 Electric Power Stations Communications NetworkingIEC 61850-3 Electric Substations Communications NetworkingEN50155 Railway - Electronic Equipment on Rolling Stock (EMC, ENV, Mech)EN50121-4 Railway - Signaling and Telecommunications ApparatusEN50121-3-2 Railway - Apparatus for Rolling Stock ODVA Industrial EtherNet/IPPROFINET conformance BIP30 (per EN60529) Safety standards andcertifications Information Technology Equipment:UL/CSA 60950-1EN 60950-1CB to IEC 60950-1 with all country deviationsNOM to NOM-019-SCFI (through partners and distributor)Industrial Floor (Control Equipment):UL 508CSA C22.2, No 142Hazardous Locations:ANSI/ISA 12.12.01 CSA C22.2 No 213IEC 60079-0, -15 IECEx test reportEN 60079-0, -15 ATEX certification (Class I Zone 2) Cabinet enclosure required Humidity Relative humidity of 5% to 95% non-condensingIEC 60068-2-3IEC 60068-2-30 Shock and vibration IEC 60068-2-27 (operational shock, 50G, 11ms, Half Sine)IEC 60068-2-27 (Non-Operational Shock, 65-80G, 9ms, Trapezoidal)IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Operational Vibration)IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Non-operational Vibration) Corrosion ISO 9223: Corrosionclass C3-Mediumclass C4-HighEN 60068-2-52 (Salt Fog)EN 60068-2-60 (Flowing Mixed Gas) [/specifications][accesories] Accessories and License Upgrade PIDs SD-IE-1GB IE 1GB SD Memory Card - Spare STK-RACK-DINRAIL 19 in. DIN Rail mount kit IE-LICENSE-SPARE Spare license for software upgrade (L2 to L3 features or MRP protocols) L-IE4000-RTU= IE4000 Electronic software license upgrade from LAN base L2 to IP Services L3 features LIC-MRP-MANAGER MRP Ring Manager license LIC-MRP-Client MRP Ring Client license Cisco ONE„ Licenses C1F1PIE4K5K1K9 Cisco ONE Foundation Lite PerpetualIncludes Prime Infrastructure (LF and AS), Identity Services Engine - Base C1F1PIE40001K9 Cisco ONE Foundation PerpetualIncludes Full flexible Netflow, Stealthwatch, Prime Infrastructure, and Identity Services Engineer - Base C1A1PIE40001K9 Cisco ONE Advanced PerpetualIncludes IP Services C1-FLOW-IE4K Cisco ONE Netflow IE4000 C1A1AIE40001K9 Cisco ONE Advanced Perpetual - IE 4000 C1F1AIE40001K9 Cisco ONE Foundation Perpetual - IE 4000, BROWNFIELD C1F1AIE4K5K1K9 Cisco ONE Foundation Lite Perpetual - IE 4000/5000 C1F1PIE40001K9 Cisco ONE Foundation Perpetual - IE 4000 Cisco IE 4000 DNA licenses IE4000-DNA-E-L Cisco DNA Essentials license (up to 12 ports) IE4000-DNA-E-L-3Y Cisco DNA Essentials 3 year term license (up to 12 ports) option IE4000-DNA-E-L-5Y Cisco DNA Essentials 5 year term license (up to 12 ports) option IE4000-DNA-A-L Cisco DNA Advantage license (up to 12 ports) IE4000-DNA-A-L-3Y Cisco DNA Advantage 3 year term license (up to 12 ports) option IE4000-DNA-A-L-5Y Cisco DNA Advantage 5 year term license (up to 12 ports) option IE4000-DNA-E-L-7Y Cisco DNA Essentials 7 year term license (up to 12 ports) option IE4000-DNA-A-L-7Y Cisco DNA Advantage 7 year term license (up to 12 ports) option IE 4000 Series Power Supplies PWR-IE50W-AC= 50W AC Power Supply PWR-IE50W-AC-L= 50W AC-L Power Supply PWR-IE65W-PC-AC= 65W PC-AC Power Supply PWR-IE65W-PC-DC= 65W PC-DC Power Supply PWR-IE170W-PC- AC= 170W PC-AC Power Supply PWR-IE170W-PC- DC 170W PC-DC Power Supply PWR-IE240W-PCAC-L 240W PCAC-L Power Supply PWR-IE480W-PCAC-L 480W PCAC-L Power Supply SFPs GLC-FE-100FX-RGD= 100BASE-FX Rugged SFP for Fast Ethernet SFP Ports GLC-FE-100LX-RGD 100BASE-LX10 Rugged SFP for Fast Ethernet SFP Ports GLC-FE-100FX= 100BASE-FX SFP for Fast Ethernet SFP Ports GLC-FE-100LX= 100BASE-LX10 SFP for Fast Ethernet SFP Ports GLC-FE-100EX= 100BASE-EX for Fast Ethernet SFP Ports GLC-FE-100ZX= 100BASE-ZX for Fast Ethernet SFP Ports GLC-FE-100BX-D= 100BASE-BX10-D SFP for Fast Ethernet SFP Ports GLC-FE-100BX-U= 100BASE-BX10-U SFP for Fast Ethernet SFP Ports GLC-SX-MM-RGD= 1000BASE-SX short wavelength; rugged GLC-LX-SM-RGD= 1000BASE-LX/LH long wavelength; rugged GLC-ZX-SM-RGD= 1000BASE-ZX extended distance; rugged GLC-BX40-U-I= 1000BASE-BX40-U for 40km Single-Fiber Bidirectional Applications; with DOM GLC-BX40-D-I= 1000BASE-BX40-D for 40km Single-Fiber Bidirectional Applications; with DOM GLC-BX40-DA-I= 1000BASE-BX40-D (Alternative) for 40km Single-Fiber Bidirectional Applications; with DOM GLC-BX80-U-I= 1000BASE-BX80-U for 80km Single-Fiber Bidirectional Applications; with DOM GLC-BX80-D-I= 1000BASE-BX80-D for 80km Single-Fiber Bidirectional Applications; with DOM GLC-SX-MMD= 1000BASE-SX short wavelength; with DOM GLC-LH-SMD= 1000BASE-LX/LH long-wavelength; with DOM GLC-EX-SMD= 1000BASE-EX long-wavelength; with DOM GLC-ZX-SMD= 1000BASE-ZX extended distance; with DOM GLC-BX-D= 1000BASE-BX10-D downstream bidirectional single fiber; with DOM GLC-BX-U= 1000BASE-BX10-U upstream bidirectional single fiber; with DOM GLC-BX-D-I= 1000BASE-BX10-D downstream bidirectional single fiber, (IND) rated, with DOM GLC-BX-U-I= 1000BASE-BX10-U upstream bidirectional single fiber, (IND) rated, with DOM CWDM-SFP-xxxx= (8 freq) Longwave xxxx-nm laser, single mode DWDM-SFP-xxxx= (40 freq) 1000BASE-DWDM SFP SFP-GE-S= Cisco SFP-GE-S Duplex SFP 1Gbps 500m MMF DDM 850nm SFP-GE-L= 1000BASE-LX/LH SFP (DOM) SFP-GE-Z= Cisco 1000BASE-ZX SFP transceiver module for SMF GLC-SX-MM= Cisco GLCSXMM SFP, Duplex, 1Gbps, 500m, 7.5dB, MMF, 850nm GLC-LH-SM= Cisco Glc Lh Sm 1000Base Lh Sm Sfp Transceiver Module GLC-ZX-SM= Cisco 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength,commercial operating temperature range. GLC-TE= 1000BASE-T standard GLC-T-RGD= 1000BASE-T standard [/accesories] Cisco IE-4000-16T4G-E Industrial Ethernet Switch The Cisco IE-4000-16T4G-E is a high-performance industrial Ethernet switch designed to provide reliable and secure network connectivity in harsh and demanding environments. This switch features 16 Fast Ethernet ports and 4 Gigabit SFP uplinks, making it an ideal solution for connecting critical industrial devices such as IP cameras, sensors, and controllers. The IE-4000-16T4G-E is engineered to operate under extreme conditions, ensuring continuous operation while offering advanced Layer 2 and Layer 3 management features for effective network segmentation, security, and traffic control. Key Features: 16 x Fast Ethernet Ports: Provides reliable and efficient data connectivity for various industrial devices, ensuring stable network communication. 4 x Gigabit SFP Uplinks: Offers flexible uplink options with fiber connectivity, enabling high-speed data transfer and network scalability. Ruggedized Design: Built to withstand extreme temperatures, shock, and vibration, making it suitable for challenging industrial environments. Layer 2 and Layer 3 Management: Includes advanced features such as VLANs, QoS, and routing protocols to enhance network control, security, and traffic management. High-Availability Design: Supports redundancy features to ensure continuous network operation in mission-critical applications. Compact Form Factor: Designed for space-constrained installations, making it suitable for industrial enclosures and cabinets. Technical Overview: Recommended for: Industrial environments requiring robust Ethernet connectivity with advanced management and high-availability features. Ports: 16 x Fast Ethernet ports, 4 x Gigabit SFP uplinks. Operating Temperature: Designed to operate in a wide temperature range, suitable for extreme industrial applications. Management: Managed through a web interface, CLI, SNMP, and Cisco DNA Center for comprehensive network setup and monitoring. Form Factor: Rugged, compact design suitable for space-constrained industrial environments. You can check the related tab for the Cisco IE-4000-16T4G-E datasheet.
More you might like
Related
Cisco IE-4000-4GC4GP4G-E Layer 3 Switch
Related
IE-4000-4GC4GP4G-E Cisco Industrial Ethernet 4000 Managed Sw
Related
IE-4000-4GC4GP4G-E
Related