Electrical data Frequency AC [Hz] 47...64 Operating voltage tolerance [%] 10 Operating voltage [V] automatic range selection Nominal voltage AC [V] 110 / 230 Input voltage range AC [V] 100...120 / 200...240 Protection class I Overvoltage protection yes; (< 36 V) Max. power-on delay time [ms] 900 Output voltage AS-i [V] 30.5 Output power (permanent) [W] 122 Output power (peak) [W] 134 Note on output power (peak) [W] briefly to load bus capacities after power on Power factor (nominal voltage 120 V AC / 60 Hz) 0.56 Power factor (nominal voltage 230 V AC / 50 Hz) 0.47 Power reserve [%] 10 Number of output circuits 1 Output current AS-i [A] 4 Max. residual ripple [mV] 50 Switch-on peak current (nominal voltage 120 V AC / 60 Hz) [A] 3 Switch-on peak current (nominal voltage 230 V AC / 50 Hz) [A] 3 Inrush current limitation yes Efficiency (nominal voltage 120 V AC / 60 Hz) [%] 88 Efficiency (nominal voltage 230 V AC / 50 Hz) [%] 89.3 External input protection ≤ B-10 A / ≤ C-6 A Derating [W/K] 3 (60...70 °C) Mains buffering time (nominal voltage 120 V AC / 60 Hz) [ms] 70 Mains buffering time (nominal voltage 230 V AC / 50 Hz) [ms] 70 Input current (nominal voltage 120 V AC / 60 Hz) [A] 2.05 Input current (nominal voltage 230 V AC / 50 Hz) [A] 1.23 Power loss (nominal voltage 120 V AC / 60 Hz) [W] 16.6 Power loss (nominal voltage 230 V AC / 50 Hz) [W] 14.6 Integrated data decoupling yes Back feeding protection [V] 35 Outputs Short-circuit proof yes Overload protection yes Overload performance constant output current Parallel connection of outputs possible no Series connection of outputs possible no Operating conditions Ambient temperature [°C] -25...70 Note on ambient temperature observe the free space for convection (see operating instructions) Storage temperature [°C] -40...85 Max. relative air humidity [%] 95; (IEC 60068-2-30) Protection IP 20 Degree of soiling 2; (IEC 62103: conductive soiling not permitted) Tests / approvals EMC EN 61000-6-1 EN 61000-6-2 EN 61000-6-4 Vibration resistance IEC 60068-2-6 ± 1,6 mm 2...17,8 Hz / 2 g 17,8...500 Hz Shock resistance IEC 60068-2-27 30 g 6 ms / 20 g 11 ms MTTF [years] 90 AS-i classification AS-i certificate 98601 Mechanical data Weight [g] 625.5 Type of mounting rail; (TH35 (EN 60715)) Dimensions [mm] 124 x 40 x 120 Material steel sheet Displays / operating elements Display AS-i voltage LED, green Remarks Pack quantity 1 pcs. Electrical connection Connection screw terminals: Diagrams and graphs Block diagram Output curve Characteristic curve for degree of efficiency / power loss