Application Application data storage via IO-Link Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 50 Protection class III Memory size [bit] 1042432 Memory type FRAM Max. read cycles unlimited Max. write cycles unlimited Interfaces Communication interface IO-Link Transmission type COM3 (230,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Device Identification SIO mode no Required master port class A Supported DeviceIDs Type of operation DeviceID default 1423 Operating conditions Ambient temperature [°C] -20...60 Storage temperature [°C] -25...80 Protection IP 67; IP 69K Tests / approvals EMC EN IEC 61000-6-2 EN IEC 61000-6-4 Shock resistance EN 60068-2-27 40 g 6 ms / repetitive EN 60068-2-27 50 g 11 ms / not repetitive Vibration resistance EN 60068-2-6 20 g 10...2000 Hz UL approval Ta -20...60 °C Enclosure type Type 1 voltage supply Limited Voltage/Current File number UL E205959 Mechanical data Weight [g] 59.8 Housing rectangular Mounting non-flush mountable Dimensions [mm] 20 x 7 x 48 Material PBT; TPU (urethane); stainless steel Displays / operating elements Display Power 1 x LED, green Memory access 1 x LED, yellow Remarks Pack quantity 1 pcs. Electrical connection Connection Cable: 1 m, PUR; 3 x 0.14 mm² Connection Connector: 1 x M12; coding: A