Application System gold-plated contacts Application display of all process values of the sensors connected to the same master Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 47 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Software / programming Parameter setting options display, indication Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud); COM3 (230,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO mode no Required master port class A Min. process cycle time [ms] 11.2 Supported DeviceIDs Type of operation DeviceID default 824 Operating conditions Ambient temperature [°C] 0...60 Storage temperature [°C] -20...80 Protection IP 65; IP 67 Tests / approvals EMC DIN EN 61000-6-2 DIN EN 61000-6-4 Shock resistance DIN EN 60068-2-27 5 g (11 ms) Vibration resistance DIN EN 60068-2-6 5 g (10...50 Hz) MTTF [years] 398 Mechanical data Weight [g] 171.5 Material stainless steel (1.4404 / 316L); PC; PBT-GF30; PPS; FKM; Displays / operating elements Display Color display 1,44", 128 x 128 pixels 2 x LED, yellow Remarks Pack quantity 1 pcs. Electrical connection - plug Connection Connector: 1 x M12; coding: A; Contacts: gold-plated