Product characteristics Electrical design PNP Output function 2 x OSSD (A1 and A2) Enable zone [mm] > 11.5 Housing Threaded type Dimensions [mm] M18 x 1 / L = 60 Application System gold-plated contacts Type of operation permanent operation Safety-related function safe state when damped correctly Application Use in mobile and harsh applications Electrical data Operating voltage [V] 8...32 DC Rated insulation voltage [V] 60 Current consumption [mA] < 20 Protection class III Reverse polarity protection yes Max. power-on delay time [ms] 1000 Outputs Electrical design PNP Output function 2 x OSSD (A1 and A2) Max. voltage drop switching output DC [V] 2.5; (30 mA) Minimum load current [mA] 1 Permanent current rating of switching output DC [mA] 50 Switching frequency DC [Hz] 10 Output data Interface type C class 1 Output voltage at 24 V compatible with EN 61131-2 inputs type 1, 2 Short-circuit protection yes Overload protection yes Max. capacitive load CL_max [nF] 20 Monitoring range Enable zone [mm] > 11.5 Safe switch-off distance s(ao) [mm] < 6.5 Accuracy / deviations Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.4 / copper: 0.3 Hysteresis [% of Sr] 1...10 Reaction times Response time to safety request [ms] 5 Response time when approaching the enable zone [ms] 5 Risk time (response time for safety-related faults) [ms] 100 Operating conditions Ambient temperature [°C] -40...85 Max. relative air humidity [%] 50; (70 °C; 50 %) Max. height above sea level [m] 5000 Ionizing radiation not permissible Protection IP 65; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on) Chemical media test according to ISO 16750-5 the following media were tested for 22 hours at 60 °C Coolants (HoughtonHocut4480 Oemeta HYCUT ET 46) The following media were tested for 22 hours at 75 °C hydraulic fluids (Fuchs Renoling B15 VG 46 HLP Total BiohydranTMP 4HEES Fuchs Hydrotherm 46 M HFC) transmission oils (Fuchs TITAN ATF 3353 Dexron III) diesel biodiesel urea (AdBlue) brake fluid (K2 TURBO DOT 4) the following media were tested for 22 hours at 23 °C corrosion protection (Sonax special preservation wax ) cold cleaner (Sonax cold cleaner S ) ammonia-based cleaner (Weco Dr. Webers Salmiak-Konzentrat (concentrated ammonium chloride) ) battery acid the following media were tested for 2 hours at 23 °C wheel rim cleaner (Sonax Xtreme Plus) the following media were tested for 10 minutes at 23 °C premium-grade petrol lead-free Tests / approvals EMC industrial environments EN 60947-5-3 EN 61000-4-2 ESD 6 kV CD / 8 kV AD EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 2 kV EN 61000-4-6 HF conducted 10 V EN 61000-4-8 30 A/m 50/60 Hz / 1000 A/m 0 Hz EN 55011 class B Mobile applications only for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems ISO 10605 ESD 8 kV CD / 15 kV AD ISO 11452-2, ISO 11452-5 radiated immunity 100 V/m ISO 7637-2, ISO 16750-2 conducted immunity 12 V / 24 V pulse 1 2a 3a 3b 4 5b Severity level III III III III III III 58V Failure criterion B B B A A C/B A EN 55025 Vibration resistance EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes Broadband noise EN 60068-2-64 h 5,9 g (10...2000 Hz) / effective acceleration for chassis mounting