Product characteristics Output function normally closed Sensing range [mm] 30...120 Housing tubular Dimensions [mm] Ø 164 / L = 63 Electrical data Frequency AC [Hz] 47...63 Operating voltage [V] 90...250 AC Protection class II Reverse polarity protection no Outputs Output function normally closed Max. voltage drop switching output AC [V] 11 Minimum load current [mA] 15 Max. leakage current [mA] 6 Permanent current rating of switching output AC [mA] 200; (250 (...50 °C)) Short-time current rating of switching output [mA] 1500; (10 ms / 0,5 Hz) Switching frequency AC [Hz] 3 Short-circuit proof no Overload protection no Monitoring range Sensing range [mm] 30...120 Sensing range adjustable yes Factory setting sensing range [mm] 120 Real sensing range Sr [mm] 120 ± 10 % Accuracy / deviations Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.3 / copper: 0.2 Hysteresis [% of Sr] < 15 Switch-point drift [% of Sr] -15...15 Operating conditions Ambient temperature [°C] -20...70 Protection IP 65 Tests / approvals EMC EN 60947-5-2 Mechanical data Weight [g] 1231 Housing tubular Mounting non-flush mountable Dimensions [mm] Ø 164 / L = 63 Material housing: PBT; bottom cover: aluminum Displays / operating elements Display Switching status 1 x LED, yellow Electrical connection Required protection miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting Remarks Remarks Recommendation: check the unit for reliable function after a short circuit. Pack quantity 1 pcs. Electrical connection Connection Cable: 2 m, PVC; 2 x 0.5 mm²