Product characteristics Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Factory setting hydrous coolants; water; media similar to water Probe length L [mm] 472 Application System gold-plated contacts Media hydrous coolants; oils; oil-based media; water; media similar to water Dielectric constant of the medium > 2 Cannot be used for extremely conductive media; adhering media; granulates; bulk material; acids; alkali; food and electroplating industry Maximum speed of the change of level [mm/s] 200 Tank pressure [bar] 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) Coolants Medium temperature [°C] 0...35; (with climate tube E43101: 35...60 °C) Oil Medium temperature [°C] 0...70 Medium temperature short time [°C] 0...90; (< 1 h) Water Medium temperature [°C] 0...35; (with climate tube E43101: 35...60 °C) Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 50 Protection class III Reverse polarity protection yes Power-on delay time [s] < 3 Measuring principle capacitive Inputs / outputs Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analog signal; IO-Link Electrical design PNP/NPN Number of digital outputs 1 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 200 Number of analog outputs 1 Analog current output [mA] 4...20, invertible Max. load [Ω] 500 Analog voltage output [V] 0...10, invertible Min. load resistance [Ω] 2000 Short-circuit protection yes Type of short-circuit protection thermal, pulsed Overload protection yes Measuring/setting range Factory setting hydrous coolants; water; media similar to water Probe length L [mm] 472 Active range A [mm] 390 Inactive range I1 / I2 [mm] 60 / 22 Setting range Set point SP [mm] 35...390 Reset point rP [mm] 30...385 Hysteresis [mm] 5 Reference point OP [mm] 139 - 163 - 188 - 212 - 236 - 261 - 285 - 310 - 334 - 358 - 383 - 407 - OFF Hysteresis, OP [mm] 3 Accuracy / deviations Measuring error [% of the final value] ± 5 Repeatability ± 2 Resolution [mm] 5 Zero signal (voltage) [V] 0 Zero signal (current) [mA] 4.0 Full signal (voltage) [V] 10 Full signal (current) [mA] 20 Software / programming Parameter setting options hysteresis / window; normally open / closed; switching logic; current/voltage output; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO mode yes Required master port class A Process data analog 2 Process data binary 1 Min. process cycle time [ms] 3.2 Supported DeviceIDs Type of operation DeviceID default 650 Operating conditions Ambient temperature [°C] 0...60 Storage temperature [°C] -25...80 Protection IP 67