Product characteristics Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Probe length L [mm] 100...1600 Process connection threaded connection G 3/4 external thread Application System gold-plated contacts Application for industrial applications Media Liquids Dielectric constant of the medium ≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation) Recommended media water; water-based media; oils; oil-based media Cannot be used for See the operating instructions, chapter "Function and features". Process temperature [°C] -25...80; (90 < 1 h ; see note under remarks) Pressure rating [bar] 16 Vacuum resistance [mbar] -1000 MAWP (for applications according to CRN) [bar] 16 Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 30 Protection class III Reverse polarity protection yes Power-on delay time [s] < 3 Measuring principle guided wave radar Inputs / outputs Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analog signal; IO-Link Electrical design PNP Number of digital outputs 1 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 200 Number of analog outputs 1 Analog current output [mA] 4...20, invertible; (scalable) Max. load [Ω] 500 Analog voltage output [V] 0...10, invertible; (scalable) Min. load resistance [Ω] 2000 Short-circuit protection yes Type of short-circuit protection thermal, pulsed Overload protection yes Measuring/setting range Probe length L [mm] 100...1600 Active range A [mm] L-40; (when set to oil and oil based media: L-60) Inactive range I1 / I2 [mm] 30 / 10; (when set to oil and oil based media: 30 / 30) Sampling rate [Hz] 4 Setting range Set point SP [mm] 15...L-30 Note on setpoint SP when set to oil and oil based media: 35...L-30 Reset point rP [mm] 10... L-35 Note on reset point rP when set to oil and oil based media: 30...L-35 In steps of [mm] 5 Hysteresis [mm] > 5 Accuracy / deviations Repeatability [mm] ± 5 Measuring error [mm] ± 7 Offset error [mm] 5 Resolution [mm] 1 Zero signal (voltage) [V] 0 Zero signal (current) [mA] 4.0 Full signal (voltage) [V] 10 Full signal (current) [mA] 20 Temperature drift per 10 K ± 0.2 Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 CDV Profiles no profile SIO mode yes Required master port class A Process data analog 1 Process data binary 1 Min. process cycle time [ms] 2.3 Supported DeviceIDs Type of operation DeviceID default 344 Operating conditions Ambient temperature [°C] -25...60 Storage temperature [°C] -40...80 Protection IP 67 Tests / approvals