Product characteristics Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Process connection G 1 Aseptoflex Vario Application System gold-plated contacts Dielectric constant of the medium ≥ 2 Recommended media water; water-based media Medium temperature [°C] -40...150; (see diagram:) Maximum speed of the change of level [mm/s] 200 Pressure rating [bar] 8 Note on pressure rating 0 bar at medium temperature < - 20 C Vacuum resistance [mbar] -1000 MAWP (for applications according to CRN) [bar] 8 Radio approval for EU/RED; United Kingdom; South Korea; USA; Canada; Australia; New Zealand; Vietnam; Singapore Note on radio approval The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”. Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 80 Protection class III Reverse polarity protection yes Power-on delay time [s] < 15 Measuring principle FMCW (80 GHz technology); frequency range 77 - 81 Hz Inputs / outputs Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analog signal; IO-Link Electrical design PNP/NPN Number of digital outputs 1; (2 configurable) Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 50 Number of analog outputs 1 Analog current output [mA] 4...20, invertible; (scalable) Max. load [Ω] 43,5 * (Ub – 18) + 600 Ω Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range [m] 10; (see diagram:) Sampling rate [Hz] > 3 Accuracy / deviations Accuracy ± 2 mm Resolution [mm] 1 Zero signal (current) [mA] 3.8 Full signal (current) [mA] 20.5 Temperature drift per 10 K ± 1 mm Reaction times Response time [ms] 330 Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor ED2: SSCs (0x8001), Measuring Sensor (0x000A) SIO mode yes Required master port class A Process data analog 1 Process data binary 2 Min. process cycle time [ms] 6 Supported DeviceIDs Type of operation DeviceID default 1324 Operating conditions Ambient temperature [°C] -40...80 Note on ambient temperature see diagram: Storage temperature [°C] -40...90 Protection IP 68; IP 69K Tests / approvals EMC DIN EN 61326-1 group 1: Class A (IO-Link active); B (IO-Link not active, with analog and switching outputs) Shock resistance DIN EN 60068-2-27 50 g (11 ms) / 20 g (6 ms) Vibration resistance IEC 61298-3 2 g (10...1000 Hz) MTTF [years] 330 Mechanical data Weight [g] 727.15 Material stainless steel (1.4404 / 316L); PA; FKM; FVMQ