Product characteristics Electrical design NAMUR Output function normally closed Sensing range [mm] 35 Housing rectangular Dimensions [mm] 40 x 40 x 66 Application System gold-plated contacts Electrical data Connection at circuit amplifier yes Switching amplifiers connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW Nominal voltage DC [V] 8.2; (1kΩ) Supply voltage DC [V] 7.5...30; (when used outside the hazardous area) Current consumption [mA] < 1; (disabled; conductive: > 2,1) Protection class III Outputs Electrical design NAMUR Output function normally closed Permanent current rating of switching output DC [mA] 30; (when used outside the hazardous area) Switching frequency DC [Hz] 100 Monitoring range Sensing range [mm] 35 Real sensing range Sr [mm] 35 ± 10 % Accuracy / deviations Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.3 Hysteresis [% of Sr] 1...15 Switch-point drift [% of Sr] -10...10 Operating conditions Ambient temperature [°C] -20...70 Protection IP 67 Tests / approvals Approval BVS 04 ATEX E 091 X; IECEx BVS 06.0003 ATEX marking II 2G Ex ia IIB T6 Gb II 1D Ex ia IIIC T 90°C Da EMC EN 60947-5-6 Shock/vibration resistance 30 g (11 ms) / 10-55 Hz (1 mm) MTTF [years] 2935 Safety classification Max. internal capacitance [nF] 220 Max. internal inductance [µH] 710 Mechanical data Weight [g] 189 Housing rectangular Mounting non-flush mountable Dimensions [mm] 40 x 40 x 66 Material housing: PPE; sensing face: PPE orange; end cap: PPS; Mounting adapter: PPS black; screw: steel galvanized Displays / operating elements Display Switching status 1 x LED, yellow Accessories Items supplied Mounting bracket: 1 Allen key: 1 Remarks Remarks 5 positions of the active zone possible Pack quantity 1 pcs. Electrical connection - plug Connection Connector: 1 x M12; coding: A; Locking: brass, white bronze coated; Contacts: gold-plated