Product characteristics Type of light red light Housing rectangular Application Design Fiber optic amplifiers for acrylic fibers, Type OBF Electrical data Operating voltage [V] 10...30 DC Current consumption [mA] < 50 Protection class III Reverse polarity protection yes Type of light red light Wave length [nm] 630 Outputs Electrical design PNP/NPN; (Automatic load detection PNP/NPN) Output function light-on/dark-on mode; (programmable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 100 Switching frequency DC [Hz] 3000 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Time function [s] 0.001...0.09 Monitoring range Range [m] 0...2; (Through-beam sensor) Range [mm] 0...100; (Diffuse reflection sensor) Range adjustable yes Operating conditions Ambient temperature [°C] -25...60 Protection IP 65 Tests / approvals EMC EN 60947-5-2 MTTF [years] 837 Mechanical data Weight [g] 48 Housing rectangular Dimensions [mm] 36 x 15 x 60 Material PPE modified Lens alignment Side sensing Displays / operating elements Display Switching status 1 x LED, yellow Power 1 x LED, green Unsafe zone 1 x LED, red Excess gain 4 x LED, green Remarks Remarks light-on mode corresponds to the NC output function for through-beam fibers corresponds to the NO output function for diffuse-reflection fibers dark-on mode corresponds to the NO output function for through-beam fibers corresponds to the NC output function for diffuse-reflection fiber optics cULus - Class 2 source required Pack quantity 1 pcs. Electrical connection Connector: 1 x M8; coding: A Diagrams and graphs excess gain graph x: Abstand [mm] y: Funktionsreservefaktor