Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Measuring range -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa Process connection threaded connection G 1/4 external thread Internal thread:M5; DIN EN ISO 1179-2 Application System gold-plated contacts Measuring element ceramic-capacitive pressure measuring cell Application for industrial applications Media liquids and gases Medium temperature [°C] -25...80 Min. bursting pressure 30000 mbar 435 psi 3000 kPa Pressure rating 10000 mbar 145 psi 1000 kPa Vacuum resistance [mbar] -1000 Type of pressure relative pressure Electrical data Operating voltage [V] 18...30 DC; (to SELV/PELV) Current consumption [mA] < 35 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] 0.3 Integrated watchdog yes Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analog signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 250 Switching frequency DC [Hz] < 500 Number of analog outputs 1 Analog current output [mA] 4...20; (scalable 1:5) Max. load [Ω] 500 Analog voltage output [V] 0...10; (scalable 1:5) Min. load resistance [Ω] 2000 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa Set point SP -985...1000 mbar -14.3...14.5 psi -98.5...100 kPa Reset point rP -995...990 mbar -14.45...14.4 psi -99.5...99 kPa Analog start point -1000...600 mbar -14.5...8.7 psi -100...60 kPa Analog end point -600...1000 mbar -8.7...14.5 psi -60...100 kPa In steps of 5 mbar 0.05 psi 0.5 kPa Accuracy / deviations Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1) Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1) Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months) Temperature coefficient zero point [% of the span / 10 K] 0,2; (-25...80 °C) Temperature coefficient span [% of the span / 10 K] 0,2; (-25...80 °C) Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% Reaction times Response time [ms] < 1.5 Delay time programmable dS, dr [s] 0...50 Damping process value dAP [s] 0...4 Damping for the analog output dAA [s] 0...4 Max. response time analog output [ms] 3 Software / programming Parameter setting options hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud)