Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Measuring range -0.1...1.6 bar -100...1600 mbar -1.46...23.2 psi -10...160 kPa Process connection threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop. Application System gold-plated contacts Application flush mountable for the food and beverage industry Media viscous media and liquids with suspended particles; liquids and gases Medium temperature [°C] -25...125; (145 max. 1h) Min. bursting pressure 40000 mbar 580 psi 4000 kPa Pressure rating 15000 mbar 215 psi 1500 kPa Vacuum resistance [mbar] -1000 Type of pressure relative pressure No dead space yes MAWP (for applications according to CRN) [bar] 15 Electrical data Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Integrated watchdog yes 2-wire Operating voltage [V] 20...32 DC Current consumption [mA] 3.6...21 Power-on delay time [s] 1 3-wire Operating voltage [V] 18...32 DC Current consumption [mA] < 45 Power-on delay time [s] 0.5 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analog signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Number of analog outputs 1 Analog current output [mA] 4...20, invertible; (scalable) Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes 2-wire Max. load [Ω] 300 3-wire Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 250 Switching frequency DC [Hz] 125 Max. load [Ω] (Ub - 10 V) / 20 mA Measuring/setting range Measuring range -0.1...1.6 bar -100...1600 mbar -1.46...23.2 psi -10...160 kPa Set point SP -96...1600 mbar -1.4...23.2 psi -9.6...160 kPa Reset point rP -100...1598 mbar -1.44...23.16 psi -10...159.8 kPa Analog start point -100...1200 mbar -1.46...17.42 psi -10...120 kPa Analog end point 300...1600 mbar 4.34...23.2 psi 30...160 kPa In steps of 2 mbar 0.02 psi 0.2 kPa Factory setting SP1 = 0.4 bar rP1 = 0.368 bar SP2 = 1.2 bar rP2 = 1.168 bar ASP = 0.0 bar AEP = 1.6 bar Accuracy / deviations Switch point accuracy [% of the span] < ± 0,2; (Turn down 1:1) Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) Characteristics deviation [% of the span] < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1) Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1) Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year) Temperature coefficient zero point [% of the span / 10 K] < ± 0,05; (0...70 °C) Temperature coefficient span [% of the span / 10 K] < ± 0,15; (0...70 °C) Reaction times