Product characteristics Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Measuring range -0.005...0.1 bar -5...100 mbar -0.073...1.45 psi -0.5...10 kPa Process connection threaded connection G 1 external thread Aseptoflex Vario Application System gold-plated contacts Measuring element ceramic-capacitive pressure measuring cell Temperature monitoring no Application flush mountable for the food and beverage industry Media viscous media and liquids with suspended particles; liquids and gases Medium temperature [°C] -25...150 Min. bursting pressure 30000 mbar 435 psi 3000 kPa Pressure rating 4000 mbar 58 psi 400 kPa Vacuum resistance [mbar] -1000 Type of pressure relative pressure No dead space yes MAWP (for applications according to CRN) [bar] 4 Electrical data Operating voltage [V] 18...30 DC Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Measuring principle hydrostatic Integrated watchdog yes 2-wire Current consumption [mA] 3.5...21.5 Power-on delay time [s] 1 3-wire Current consumption [mA] < 45 Power-on delay time [s] 0.5 Inputs / outputs Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal analog signal; IO-Link; (configurable) Number of digital outputs 1; (IO-Link) Number of analog outputs 1 Analog current output [mA] 4...20; (scalable) Max. load [Ω] 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) Short-circuit proof yes Overload protection yes Measuring/setting range Measuring range -0.005...0.1 bar -5...100 mbar -0.073...1.45 psi -0.5...10 kPa Analog start point -5...80 mbar -0.073...1.16 psi -0.5...8 kPa Analog end point 15...100 mbar 0.218...1.45 psi 1.5...10 kPa In steps of 0.05 mbar 0.001 psi 0.005 kPa Factory setting ASP = 0.0 mbar AEP = 100 mbar Accuracy / deviations Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) Characteristics deviation [% of the span] < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) Linearity deviation [% of the span] < ± 0,25; (Turn down 1:1) Hysteresis deviation [% of the span] < ± 0,2; (Turn down 1:1) Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year) Total deviation over temperature range Temperature range total deviation -25...15 °C Characteristics deviation ± 0,15 % of the span / 10 K 15...80 °C Characteristics deviation 80...150 °C Characteristics deviation ± 0,2 % of the span / 10 K Notes on the accuracy / deviation for further details see section Diagrams and graphs Reaction times Damping for the analog output dAA [s] 0...4 2-wire Step response time analog output [ms] 30 3-wire Step response time analog output [ms] 7 Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) SIO mode no