Product characteristics Number of inputs and outputs Number of digital outputs: 2 Measuring range 0...100 bar 0...1450 psi 0...10 MPa Process connection threaded connection G 1/4 Internal thread Application System gold-plated contacts Measuring element ceramic-capacitive pressure measuring cell Application for industrial applications Media Liquids Conditionally suitable for use in gases at pressures > 25 bar only on request Medium temperature [°C] -25...80 Min. bursting pressure 650 bar 9400 psi 65 MPa Pressure rating 300 bar 4350 psi 30 MPa Vacuum resistance [mbar] -1000 Type of pressure relative pressure Electrical data Operating voltage [V] 18...30 DC; (to SELV/PELV) Current consumption [mA] < 35 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] < 0.3 Integrated watchdog yes Inputs / outputs Number of inputs and outputs Number of digital outputs: 2 Outputs Total number of outputs 2 Output signal switching signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 150; (200 (...60 °C) 250 (...40 °C)) Switching frequency DC [Hz] < 170 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range 0...100 bar 0...1450 psi 0...10 MPa Factory setting / CMPT = 2 Set point SP 1...100 bar 10...1450 psi 0.1...10 MPa Reset point rP 0.5...99.5 bar 5...1445 psi 0.05...9.95 MPa Min. difference between SP and rP 0.5 bar 10 psi 0.05 MPa In steps of 0.5 bar 5 psi 0.05 MPa Status_B High Resolution / CMPT = 3 Set point SP 0.8...100 bar 12...1450 psi 0.08...10 MPa Reset point rP 0.3...99.5 bar 5...1443 psi 0.03...9.95 MPa Min. difference between SP and rP 0.5 bar 8 psi 0.05 MPa In steps of 0.1 bar 1 psi 0.01 MPa Accuracy / deviations Switch point accuracy [% of the span] < ± 0,5 Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K) Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) Hysteresis deviation [% of the span] < ± 0,25 Long-term stability [% of the span] < ± 0,05; (per 6 months) Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (-0...80 °C) Temperature coefficient span [% of the span / 10 K] < ± 0,2; (-0...80 °C) Reaction times Response time [ms] < 3 Delay time programmable dS, dr [s] 0...50 Software / programming Parameter setting options hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1