Product characteristics Number of inputs and outputs Number of digital outputs: 2 Measuring range 0...100 bar 0...1450 psi 0...10 MPa Process connection threaded connection G 1/4 external thread Internal thread:M5 Application Application for industrial applications Media liquids and gases Conditionally suitable for use in gases at pressures > 25 bar only on request Medium temperature [°C] -25...90 Min. bursting pressure 650 bar 9400 psi 65 MPa Pressure rating 300 bar 4350 psi 30 MPa Type of pressure relative pressure Electrical data Operating voltage [V] 9.6...36 DC; (communication mode: 18...32) Current consumption [mA] < 45 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] 0.3 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2 Outputs Total number of outputs 2 Output signal switching signal; IO-Link; (configurable) Electrical design PNP Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 250 Switching frequency DC [Hz] 170 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range 0...100 bar 0...1450 psi 0...10 MPa Set point SP 1...100 bar 20...1450 psi 0.1...10 MPa Reset point rP 0.5...99.5 bar 10...1440 psi 0.05...9.95 MPa In steps of 0.5 bar 10 psi 0.05 MPa Factory setting SP1 = 25.0 bar rP1 = 23.0 bar SP2 = 75.0 bar rP2 = 73.0 bar OUT1 = Hno OUT2 = Hno Accuracy / deviations Switch point accuracy [% of the span] < ± 0,5 Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K) Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) Hysteresis deviation [% of the span] < ± 0,1 Long-term stability [% of the span] < ± 0,1; (per year) Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (0...80 °C) Temperature coefficient span [% of the span / 10 K] < ± 0,2; (0...80 °C) Reaction times Response time [ms] < 3 Damping process value dAP in steps [s] 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.0 Profiles no profile SIO mode yes Required master port class A Process data analog 1 Process data binary 2 Min. process cycle time [ms] 2.3 Supported DeviceIDs Type of operation DeviceID default 4 Operating conditions Ambient temperature [°C] -25...85 Storage temperature [°C] -40...100 Protection IP 68; (7 days / 1 m water depth / 0.1 bar) Tests / approvals EMC noise immunity EN 61000-6-2 EN 61000-4-2 ESD