Product characteristics Number of inputs and outputs Number of digital outputs: 2 Measuring range 0...250 bar 0...3626 psi 0...25 MPa Process connection threaded connection 1/4" NPT external thread Internal thread:M5 Application Measuring element metallic thin film cell Application for industrial applications Media liquids and gases Medium temperature [°C] -40...90 Min. bursting pressure 1200 bar 17400 psi 120 MPa Pressure rating 625 bar 9060 psi 62.5 MPa Note on pressure rating static Vacuum resistance [mbar] -1000 Type of pressure relative pressure MAWP (for applications according to CRN) [bar] 625 Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 15 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] < 0.3 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2 Outputs Total number of outputs 2 Output signal switching signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 100 Switching frequency DC [Hz] < 170 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range 0...250 bar 0...3626 psi 0...25 MPa Set point SP 2.5...250 bar 37...3626 psi 0.25...25 MPa Reset point rP 1.3...248.8 bar 18...3608 psi 0.13...24.88 MPa In steps of 0.1 bar 1 psi 0.01 MPa Factory setting SP1 = 62.5 bar rP1 = 57.5 bar ou1 = Hno; SP2 = 187.5 bar rP2 = 182.5 bar ou2 = Hno; dS1/dS2 = 0 ms dr1/dr2 = 0 ms coF = 0 % P-n = PnP dAP= 60 ms Accuracy / deviations Switch point accuracy [% of the span] < ± 0,5 (nach DIN EN 61298-2) Repeatability [% of the span] < ± 0,05; (with temperature fluctuations < 10 K) Characteristics deviation [% of the span] < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) Linearity deviation [% of the span] < ± 0,1 (BFSL) / < ± 0,2 (LS) Hysteresis deviation [% of the span] < ± 0,2 Long-term stability [% of the span] < ± 0,1; (per 6 months) Temperature coefficient zero point [% of the span / 10 K] < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) Temperature coefficient span [% of the span / 10 K] < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) Reaction times Response time [ms] < 3 Software / programming Parameter setting options hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO mode yes Required master port class A Process data analog 2 Process data binary 2 Min. process cycle time [ms] 5 Supported DeviceIDs Type of operation DeviceID