Product characteristics Number of inputs and outputs Number of digital outputs: 2 Measuring range -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa Process connection threaded connection 1/4" NPT external thread Internal thread:M5 Application Measuring element metallic thin film cell Application for industrial applications Media liquids and gases Medium temperature [°C] -40...90 Min. bursting pressure 300 bar 4350 psi 30 MPa Pressure rating 25 bar 360 psi 2.5 MPa Note on pressure rating static Vacuum resistance [mbar] -1000 Type of pressure relative pressure; vacuum MAWP (for applications according to CRN) [bar] 25 Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 15 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] < 0.3 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2 Outputs Total number of outputs 2 Output signal switching signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 100 Switching frequency DC [Hz] < 170 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa Set point SP -0.9...10 bar -13.1...145 psi -0.09...1 MPa Reset point rP -0.95...9.95 bar -13.8...144.3 psi -0.095...0.995 MPa In steps of 0.005 bar 0.1 psi 0.0005 MPa Factory setting SP1 = 2.5 bar rP1 = 2.3 bar ou1 = Hno; SP2 = 7.5 bar rP2 = 7.3 bar ou2 = Hno; dS1/dS2 = 0 ms dr1/dr2 = 0 ms coF = 0 % P-n = PnP dAP= 60 ms Accuracy / deviations Switch point accuracy [% of the span] < ± 0,5 (nach DIN EN 61298-2) Repeatability [% of the span] < ± 0,05; (with temperature fluctuations < 10 K) Characteristics deviation [% of the span] < ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) Linearity deviation [% of the span] < ± 0,1 (BFSL) / < ± 0,2 (LS) Hysteresis deviation [% of the span] < ± 0,2 Long-term stability [% of the span] < ± 0,1; (per 6 months) Temperature coefficient zero point [% of the span / 10 K] < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) Temperature coefficient span [% of the span / 10 K] < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) Reaction times Response time [ms] < 3 Software / programming Parameter setting options hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO mode yes Required master port class A Process data analog 2 Process data binary 2 Min. process cycle time [ms] 5 Supported DeviceIDs