Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Process connection Ø 8 mm Application System gold-plated contacts Media water; glycol solutions; air; oils Note on media low-viscosity oils with viscosity: ≤ 40 mm²/s (104 °F) high-viscosity oils with viscosity: > 40 mm²/s (104 °F) Medium temperature [°F] -4...212 Pressure rating [bar] 50 Pressure rating [psi] 725 MAWP (for applications according to CRN) [bar] 50 Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 100 Protection class III Reverse polarity protection yes Power-on delay time [s] 10 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analog signal; frequency signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 250 Number of analog outputs 1 Analog current output [mA] 4...20; (scalable) Max. load [Ω] 350 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Frequency of the output [Hz] 0...1000 Measuring/setting range Probe length L [mm] 200 Operating mode relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative) Temperature monitoring Measuring range [°F] -4...212 Resolution [°F] 0.5 Liquid media - absolute operating mode Setting range [ft/s] 0.15...9.85 Greatest sensitivity [ft/s] 0.15...9.85 Liquid media - relative operating mode Setting range [ft/s] 0.15...19.5 Greatest sensitivity [ft/s] 0.15...9.85 Gases - operating mode "absolute" Setting range [ft/s] 98...328 Greatest sensitivity [ft/s] 6...328 Gases - operating mode "relative" Setting range [ft/s] 98...328 Greatest sensitivity [ft/s] 6...328 Accuracy / deviations Temperature drift [cm/s x 1/K] 0,01 fps x 1/K (< 68 °F; > 158 °F) Max. temperature gradient of medium [K/min] 100 Absolute operating mode Repeatability 0,05 m/s; (water; Flow velocity: 0,05...3 m/s) Relative operating mode Accuracy ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 68...158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) Repeatability 0,05 m/s; (water; Flow velocity: 0,05...3 m/s) Temperature monitoring Temperature drift ± 0,003 K/°F Accuracy [K] ± 0,3 / ± 1; (water; Flow velocity: 1...9,85 fps / air; Flow velocity: > 32,8 fps) Reaction times Response time [s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) Temperature monitoring Dynamic response T05 / T09 [s] 1,5 (T09); (water; Flow velocity: 1...9,85 fps) Software / programming Parameter setting options hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO mode yes Required master port class A Process data analog 2 Process data binary 2 Min. process cycle time [ms] 3