Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Measuring range 0.5...143.9 m/s 8...2110 m³/h 0.12...35.18 m³/min Process connection threaded connection G 1 Internal thread Application Installation Adjustable to inside pipe diameters; (38...254 mm) Media compressed air Medium temperature [°C] 0...60 Pressure rating [bar] 16 Pressure rating [MPa] 1.6 Pressure rating [psi] 232 MAWP (for applications according to CRN) [bar] 16 Electrical data Operating voltage [V] 18...30 DC; (to SELV/PELV) Current consumption [mA] < 110 Protection class III Reverse polarity protection yes Power-on delay time [s] 1 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable) Electrical design PNP Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 250; (per output) Number of analog outputs 1 Analog current output [mA] 4...20; (scalable) Max. load [Ω] 500 Pulse output consumed quantity meter Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range Measuring/setting range; Flow monitoring; The values apply at: Ø 72 mm Measuring range 0.5...143.9 m/s 8...2110 m³/h 0.12...35.18 m³/min Display range 0...172.7 m/s 0...2532 m³/h 0...42.22 m³/min Resolution 0.1 m/s 2 m³/h 0.02 m³/min Set point SP 1.2...143.9 m/s 18...2110 m³/h 0.28...35.18 m³/min Reset point rP 0.5...143.2 m/s 6...2100 m³/h 0.12...35 m³/min Analog start point ASP 0...107.9 m/s 0...1582 m³/h 0...26.38 m³/min Analog end point AEP 36...143.9 m/s 528...2110 m³/h 8.8...35.18 m³/min In steps of 0.1 m/s 2 m³/h 0.02 m³/min Volumetric flow quantity monitoring Pulse value 1...1000 x 10³ In steps of 1 Nm³ Pulse length [s] 0,7...2 (D = 72 mm) Temperature monitoring Measuring range [°C] 0...60 Display range [°C] -12...72 Resolution [°C] 0.2 Set point SP [°C] 0.4...60 Reset point rP [°C] 0.2...59.8 Analog start point [°C] 0...45 Analog end point [°C] 15...60 In steps of [°C] 0.2 Accuracy / deviations Flow monitoring Repeatability [% of the measured value] ± 1,5 Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); (D = 72mm, T = 22 °C; standard volume flow: 50...850 Nm³/h) Temperature monitoring Accuracy [K] ± 2,5 (Q > 2 Nm³/h) Reaction times Flow monitoring Response time [s] 0.1; (dAP = 0) Damping process value dAP in steps [s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 Temperature monitoring Dynamic response T05 / T09 [s] 30 (Q > 2 Nm³/h) Software / programming Parameter setting options Flow monitoring; quan