Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Measuring range 6...1584 gph 0.1...26.4 gpm Process connection threaded connection G 1 DN25 flat seal Application System gold-plated contacts Application Totalizer function; for industrial applications Installation connection to pipe by means of an adapter Media Conductive liquids; water; water-based media Note on media conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) Medium temperature [°F] 14...158 Pressure rating [bar] 16 Pressure rating [psi] 232 MAWP (for applications according to CRN) [bar] 11.2 Electrical data Operating voltage [V] 18...30 DC; (to SELV/PELV) Current consumption [mA] 95; (24 V) Protection class III Reverse polarity protection yes Power-on delay time [s] 5 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Inputs Inputs counter reset Outputs Total number of outputs 2 Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 200 Number of analog outputs 1 Analog current output [mA] 4...20; (scalable) Max. load [Ω] 500 Analog voltage output [V] 0...10; (scalable) Min. load resistance [Ω] 2000 Pulse output flow rate meter Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Measuring range 6...1584 gph 0.1...26.4 gpm Display range -1902...1902 gph -31.7...31.7 gpm Resolution 2 gph 0.05 gpm Set point SP 14...1586 gph 0.25...26.4 gpm Reset point rP 6...1578 gph 0.1...26.25 gpm Analog start point ASP 0...1272 gph 0...21.2 gpm Analog end point AEP 312...1586 gph 5.2...26.4 gpm In steps of 2 gph 0.05 gpm Volumetric flow quantity monitoring Pulse value 0.01...100 000 000 gal Pulse length [s] 0,0025...2 Temperature monitoring Measuring range [°F] -4...176 Resolution [°F] 0.5 Set point SP [°F] -2.5...176 Reset point rP [°F] -3.5...175 Analog start point [°F] -4...140.5 Analog end point [°F] 31.5...176 In steps of [°F] 0.5 Accuracy / deviations Flow monitoring Accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW) Repeatability ± 0,2% MEW Temperature monitoring Accuracy [K] ± 2,5 (Q > 0,26 gpm) Reaction times Flow monitoring Response time [s] 0.15; (dAP = 0, T19) Delay time programmable dS, dr [s] 0...50 Damping process value dAP [s] 0...5 Temperature monitoring Dynamic response T05 / T09 [s] T09 = 20 (Q > 0,26 gpm)