Product characteristics Measuring range -40...150 °C -40...302 °F Process connection Ø 6 mm Installation length EL [mm] 50 Application System gold-plated contacts Measuring element 1 x Pt 100; (to DIN EN 60751, class A) Application hygienic systems Media liquids and gases Pressure rating [bar] 160 Minimum installation depth [mm] 15 Electrical data Protection class III Measuring/setting range Probe length L [mm] 50 Measuring range -40...150 °C -40...302 °F Accuracy / deviations Accuracy [K] ± (0,15 K + 0,002 x|t|) Reaction times Dynamic response T05 / T09 [s] 1 / 3; (according to DIN EN 60751) Operating conditions Ambient temperature [°C] -25...80 Storage temperature [°C] -40...100 Protection IP 68; IP 69K Tests / approvals Shock resistance DIN EN 60068-2-27 50 g (11 ms) Vibration resistance DIN EN 60068-2-6 10 g (10...2000 Hz) MTTF [years] 22831 Mechanical data Weight [g] 25.5 Dimensions [mm] Ø 6 Material stainless steel (1.4404 / 316L) Materials (wetted parts) stainless steel (1.4404 / 316L) electropolished Process connection Ø 6 mm Surface characteristics Ra/Rz of the wetted parts Ra: < 0.8 Probe diameter [mm] 6 Installation length EL [mm] 50 Remarks Remarks cULus - Class 2 source required The values for accuracy apply to flowing water. Pack quantity 1 pcs. Electrical connection Connection Connector: 1 x M12; coding: A; Contacts: gold-plated