Product characteristics Frequency range [Hz] 2...10000 Measuring principle capacitive v-RMS Measuring range of vibration [mm/s] 0...45 a-Peak / a-RMS Measuring range of vibration 0...50 g 0...490.3 m/s² Application Application medium-sized machines, power < 300 kW, rotational speed 120...600 rpm Electrical data Operating voltage [V] 18...30 DC Current consumption [mA] < 50 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Type of sensor Microelectromechanical system (MEMS) Inputs / outputs Number of inputs and outputs Number of digital outputs: 2 Outputs Output signal switching signal; IO-Link Electrical design PNP/NPN; (configurable) Number of digital outputs 2 Output function normally open / closed Max. voltage drop switching output DC [V] 2 Max. current load per output [mA] 100 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Measuring/setting range Note on setpoint SP configurable Frequency range [Hz] 2...10000 Measuring principle capacitive Number of measurement axes 1 v-RMS Measuring range of vibration [mm/s] 0...45 Set point SP [mm/s] 0.2...45 Reset point rP [mm/s] 0...44.8 In steps of [mm/s] 0.2 a-Peak / a-RMS Measuring range of vibration 0...50 g 0...490.3 m/s² Set point SP 0.2...50 g 2...490.3 m/s² Reset point rP 0...49.8 g 0...488.3 m/s² In steps of 0.2 g 2 m/s² Crest Measuring range of vibration 1...50 Set point SP 2...50 Reset point rP 1...49 In steps of 1 Temperature measurement Measuring range [°C] -30...80 Resolution [°C] 0.1 Set point SP [°C] -28...80 Reset point rP [°C] -30...78 In steps of [°C] 2 Accuracy / deviations Accuracy ≤ 4 kHz +/-10 %; ≥ 4...10 kHz: < 3 dB Accuracy [K] ± 2,5 K + (0,2 x (Umgebungstemperatur - Oberflächentemperatur)) Linearity deviation 2 % Software / programming Parameter setting options Software Diagnostic functions self-test Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud); COM3 (230,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9: 2013-07 Profiles Blob (0x0030); Measuring sensor (0x800A); Common Profile (0x4000) SIO mode yes Required master port class A Process data analog 10 Process data binary 2 Min. process cycle time [ms] 3.6 IO-Link functions (acyclical) filter for v-RMS, a-RMS, a-Peak; Hysteresis; window; Switch points; switching logic Supported DeviceIDs Type of operation DeviceID Status A (COM2) 1258 Status B (COM2 / COM3) 1370 Note For further information please see the IODD PDF file at "Downloads"