IN 100-S High Precision Hall Effect Current Sensor, 100 Amp, 200mA Output, 28.2mm Aperture, +/-15V Supply Features Closed loop (compensated) current transducer using an extremely accurate zero flux detector 9-pin D-Sub male secondary connector Status signal to indicate the transducer state LED indicator confirms normal operation Metal housing to improve immunity to EMC & power dissipation Operating temperature ?40 °C to 85 °C. Advantages Very high accuracy Excellent linearity Extremely low temperature drift Wide frequency bandwidth High immunity to external fields No insertion losses Very low noise on output signal Low noise feedback to primary conductor. Applications Feedback element in high performance gradient amplifiers for MRI Feedback element in high-precision, high-stability power supplies Calibration unit Energy measurement Medical equipment. Standards EN 61000-6-2: 2005 EN 61000-6-3: 2007 EN 61010-1: 2010. Application Domain Industrial Laboratory Medical. Specification Insulation coordination Parameter Symbol Unit Value Comment RMS voltage for AC insulation test, 50 Hz, 1 min UdkV 4.2 Between primary and secondary + shield Impulse withstand voltage 1.2/50 ?s ÛWkV 8 Clearance (pri. - sec.) dCImm 11.5 Shortest distance through air Creepage distance (pri. - sec.) dCpmm 11.9 Shortest path along device body Comparative tracking index CTI600 Rated insulation RMS voltage UNmV 1000 Basic insulation according to IEC 61010-1 CAT III, PD2 Rated insulation RMS voltage 1000 Reinforced insulation according to IEC 61010-1 CAT II, PD2 Environmental and mechanical characteristics Parameter Symbol Unit Min Typ Max Comment Ambient operating temperature TA°C ?40 85 Ambient storage temperature TS°C ?40 85 Relative humidity RH% 20 80 Dimensions See drawing in page 8 Mass mkg 1.3 Electrical data At TA = 25 °C, ±UC = ±15 V DC, unless otherwise noted. Lines with a * in the comment column apply over the ?40 … 85 °C ambient temperature range. Parameter Symbol Unit Min Typ Max Comment Primary continuous direct current DC IP NA ?100 100 * Primary nominal RMS current AC IP NA ?100 100 * Peak primary current, measuring range ÎP MA ?150 150 * Measuring resistance RM? 0 1 See graph page 5 for other value Secondary current nominal IS NA ?0.200 0.200 * Number of secondary turns NS500 Resistance of secondary winding RS? 8 Overload capability 1)ÎPkA ?5 5 @ pulse of 100 ms Supply voltage DC +UCV 14.25 15 15.75 ?UC?14.25 ?15 ?15.75 Current consumption positive DC +ICA 0.12 @ IP = 0 1.12 Current consumption positive DC ?ICA 0.07 @ IP= 0 1.07 Output RMS noise current 0 … 10 Hz 2) Inoppm 0.05 0.1 Output RMS noise current 0 … 10 kHz 2)1.5 4 Output RMS noise current 0 … 160 kHz 2)3.5 10 Output peak-to-peak noise current 2)Ino ppppm 18 34 Electrical offset current + self magnetization + effect of earth magnetic field 2) IO Eppm ?10 10 * Temperature coefficient of IO E@ IP = 0 A TCIO Eppm/K ?0.3 0.3 Linearity error 2)?Lppm ?2 1 2 ?3 1 3 * Step response time to 90 % of IPN DCtrµs 1 di/dt of 100 A/?s Frequency bandwidth (±1 dB) BWkHz 230 Small-signal bandwidth, 1.5 % of IP NFrequency bandwidth (±3 dB) BWkHz 2000 Start-up time tstarts 15 Notes: 1) Single pulse only, not AC. The transducer may require a few seconds to return to normal operation when autoreset system is running 2) All ppm figures refer to full-scale which corresponds to a secondary nominal RMS current. Datasheet Product Datasheet