IN 2000-S High Precision Hall Effect Current Sensor, 2000 Amp, 1000mA Output, 70mm Aperture, +/-15V Supply For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated) current transducer using an extremely accurate zero flux detector Electrostatic shield between primary and secondary circuit 9-pin D-Sub male secondary connector Status signal to indicate the transducer state LED indicator confirms normal operation Metal housing to improve immunity to EMC & power dissipation Operating temperature −40 °C to 85 °C. Advantages Very high accuracy Excellent linearity Extremely low temperature drift Wide frequency bandwidth High immunity to external fields No insertion losses Very low noise on output signal Low noise feedback to primary conductor. Applications Feed back element in high performance gradient amplifiers for MRI Feedback element in high-precision, high-stability power supplies Calibration unit Energy measurement Medical equipment. Standards EN 61000-6-2: 2005 EN 61000-6-3: 2007 EN 61010-1: 2010. Application Domain Industrial Laboratory Medical Specification Electrical data At TA = 25 °C, ±UC = ±15 V, unless otherwise noted. Lines with a * in the comment column apply over the −40 … 85 °C ambient temperature range. Parameter Symbol Unit Min Typ Max Comment Primary continuous direct current IP N DCA −2000 2000 * Primary nominal RMS current IP NA −2000 2000 * Primary current, measuring range IP MA −3000 3000 * Measuring resistance RMΩ 0 1 See curve page 5 Secondary current nominal IS NA −1 1 * Number of secondary turns NS2000 Resistance of secondary winding RSΩ 4 Overload capability 1)ÎPkA −10 10 @ pulse of 100 ms Supply voltage ±UCV ±14.25 ±15 ±15.75 Current consumption positive +IC mA 180 200 225 Add IS for total current consumption Current consumption negative −IC80 89 100 Output RMS noise current 0 … 10 Hz 2) Inoppm 0.1 Output RMS noise current 0 … 10 kHz 2)4 Output RMS noise current 0 … 160 kHz 2)20 Output peak-to-peak noise current 2)Ino ppppm 50 Electrical offset current + self magnetization + effect of earth magnetic field 2) IO Eppm −10 10 * Temperature coefficient of IO E@ IP = 0 A TCIO Eppm/K 0.1 Offset stability 2)ppm/month −1 1 Linearity error 2)εLppm 1 2 2 3 * Step response time to 90 % of IPN DCtrµs 1 di/dt of 100 A/μs Frequency bandwidth (±1 dB) BWkHz 130 Small-signal bandwidth, 0.5 % of IP NFrequency bandwidth (±3 dB) BWkHz 140 Test current ITA 1 Number of turns (test winding) NT200 Start-up time tstarts 2 5 15 Notes: 1) Single pulse only, not AC. The transducer may require a few seconds to return to normal operation when autoreset system is running 2) All ppm figures refer to full-scale which corresponds to a secondary nominal RMS current of 1 A. Datasheet Product Datasheet