KEDRON Single Phase Voltage Regulator
/* Author: Kenton Jones Date: Dec 4, 2025 Updated: January 2026 (KEDRON Electrical Component UI) Contact: [email protected] */ @import url('https://fonts.googleapis.com/c ss2?family=Lato:wght@400;700&display=swap'); .cd-wrapper { font-family: 'Lato', sans-serif; color: #444; line-height: 1.6; margin: 0; ; } .description-container { margin: 0 auto; ; box-sizing: border-box; } .table-container { overflow-x: auto; -webkit-overflow-scrolling: touch; margin-top: 20px; display: flex; justify-content: center; } .cd-wrapper table { width: 100%; border-collapse: collapse; box-shadow: 0 2px 5px rgba(0,0,0,0.05); font-family: 'Lato', sans-serif; border-radius: 8px; overflow: hidden; } thead .cd-wrapper tr { background-color: #62a73c; color: #ffffff; text-align: left; } th, .cd-wrapper td { ; text-align: left; } tbody .cd-wrapper tr { border-bottom: 1px solid #d1ccc0; } tbody tr:nth-of-type(even) { background-color: #f7f9f5; } tbody tr:last-of-type { border-bottom: 2px solid #62a73c; } td strong { color: #333; font-weight: 700; } main .cd-wrapper ul { list-style: disc; padding-left: 25px; margin: 15px 0; } main .cd-wrapper li { margin-bottom: 8px; } h1, .cd-wrapper h2 { color: #333; word-wrap: break-word; } .cd-wrapper a { color: #62a73c; text-decoration: underline; } a:hover { color: #ffc20d; } .proactive-box { background-color: #f7f9f5; border: 1px dashed #62a73c; ; border-radius: 8px; text-align: center; margin: 25px 0; } .dark-content-box { background-color: #2b2b2b; ; margin: 20px 0; border-radius: 12px; border: 2px solid #62a73c; box-shadow: 0 4px 10px rgba(0,0,0,0.1); box-sizing: border-box; } .dark-grid { display: grid; grid-template-columns: 1fr; gap: 15px; } .dark-card { background-color: #383838; border-top: 4px solid #ffc20d; ; border-radius: 8px; transition: transform 0.2s ease; } .dark-card:hover { transform: translateY(-3px); background-color: #444; } .dark-card strong { display: block; color: #62a73c; margin-bottom: 8px; font-size: 1.1em; text-transform: uppercase; letter-spacing: 0.5px; } .dark-card .cd-wrapper p { margin: 0; font-size: 0.95em; color: #dddddd; } .card-icon { height: 32px; background-color: #62a73c; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-bottom: 12px; } .feature-checklist { background-color: #f9f9f9; border-left: 6px solid #ffc20d; ; border-radius: 0 8px 8px 0; margin: 30px 0; } .feature-item { display: flex; align-items: flex-start; margin-bottom: 12px; border-bottom: 1px solid #eee; padding-bottom: 10px; } .feature-item:last-child { border-bottom: none; margin-bottom: 0; } .check-mark { color: #62a73c; font-weight: bold; margin-right: 12px; font-size: 1.2em; flex-shrink: 0; } @media ( } .dark-grid { grid-template-columns: 1fr 1fr; } .dark-content-box { ; } } @media ( ) { .cd-wrapper h2 { font-size: 1.4em; } .dark-content-box { ; } .cd-wrapper table { } } KEDRON PowerGEN 20KW - Voltage Regulator (AVR) Protect your sensitive household electronics and ensure steady power delivery with the KEDRON PowerGEN 20KW Single Phase Voltage Regulator (AVR). As the "electrical governor" of your generator, the AVR constantly monitors the output voltage and adjusts the alternator's excitation current to maintain a stable, clean 240V/120V supply regardless of the load demand. In off-grid scenarios, voltage fluctuations can be catastrophic for modern appliances and inverter systems. This Genuine KEDRON replacement part features high-grade capacitors and advanced heat-sink technology, designed to withstand the thermal environment of the 20KW alternator while providing the rapid response necessary for flawless power quality. Off-Grid Pro-Tip: If your lights are flickering or your voltage readings are swinging wildly under steady load, the AVR is likely failing. We recommend replacing your AVR immediately to prevent an over-voltage event that could damage your transfer switch or sensitive electronics. Key Features Precision electrical management for heavy-duty power systems: ✓ Closed-Loop Control: Integrated feedback loop ensures the output voltage remains within ±1% of the set point. ✓ Under-Frequency Protection: Automatically reduces voltage output if engine RPM drops, preventing alternator overheating. ✓ Epoxy-Resin Sealed: Moisture and vibration-resistant construction designed for the high-harmonic environment of a 20KW alternator. ✓ Direct Thread/Terminal Fit: Pre-calibrated for KEDRON specifications for a seamless "plug-and-play" installation. What's Included Everything required to restore stable electrical output: 1 Automatic Voltage Regulator (AVR) High-grade electronic module with integrated heat-sink and terminal connectors. 2 Sealing/Vibration Mounts Heavy-duty hardware designed to isolate the module from the alternator's natural vibrations. When to Replace Your AVR Don't let unstable power damage your site. Replace the AVR if you observe: 1 Voltage Fluctuation The display shows voltage swinging by more than 5-10 volts while the generator is under a steady load. 2 Low Voltage Output The generator runs at correct RPM but fails to produce full rated voltage (e.g., reading 90V instead of 120V). 3 Physical Component Damage Visible swelling of capacitors or "burn" marks on the circuit board visible through the casing. 4 Loss of Excitation The engine runs normally but the generator produces zero voltage output despite healthy carbon brushes. Technical Specifications Specification Details Product Name PowerGEN 20KW Single Phase Voltage Regulator (AVR) SKU 72030020011KPG Compatibility KEDRON PowerGEN 20KW Series (Single Phase) Regulation Accuracy ±1.0% Protection Features Over-Excitation / Under-Frequency (UFRO) Warranty N/A (Replacement Part) Stable power. Protected electronics.Genuine KEDRON parts for your off-grid independence.
More you might like
Related
Littelfuse 202-200-SP Single-Phase Voltage/Phase Monitor
Related
ICM492-LF LINE VOLTAGE MONITORING, SINGLE PHASE VOLTAGE MONI
Related
""Single Phase"" Conduit & Voltage Labels
Related