Mindray V12
Modular patient monitoring system is convenient, cost-effective The Mindray V12 is a versatile patient monitor that features a modular design fully scalable to meet the demands of a variety of clinical applications. Designed to serve as both a bedside and transport monitors, medical staff can simply remove the portable V12 from the VDock to ready the unit for transport — without needed to disconnect cables or move modules. Featuring color-coded patient monitor connectors with unique key-code feature to help clinicians quickly respond to a patient’s changing condition. The Mindray V12 Patient Monitor is available professionally refurbished from Avante Health Solutions, along with a full suite of related parts and services. For more information, contact an Avante representative today. Features Monitoring parameters include: ECG, NIBP, HR, IBP, TEMP, SpO2, CO2. Versatile patient monitor with integrated module bay. Designed to serve as both a bedside and transport monitor. Modular design is fully scalable to meet the needs of each care unit. Interchangeable system elements for added convenience, affordability. Integrated wireless capability. Color-coded patient monitor connectors. Unique, key-code feature. For full availability information, contact an Avante representative. SPECIFICATIONS Display Type: 12.1 in color TFT touchscreen display Resolution: 1024 x 768 Aspect ratio: 3:4 in portrait mode Waveforms: 8 selectable Physical Dimensions Height: 13.7 in (34.8 cm) Width: 9.4 in (23.9 cm) Depth: 7.5 in (19.1 cm) Weight: 8.9 lb (4 kg) Weight (with module and 3 batteries): 13 lb (5.9 kg) Heart Range Meter Measurement Range - Adult/Pediatric: 30 – 300 bpm Measurement Range - Neonate: 30 – 350 bpm Resolution: 1 bpm Accuracy: 30 – 250 bpm: ±3 bpm or ±3%, whichever is greater 251 – 350 bpm: ±5% ST Segment Analysis Adult/Pediatric Only Measurement Range: –10.0 mm to +10.0 mm (-1000?V to +1000?V RTI) Resolution: 0.1 mm (10?V) User Selectable ST Measurement Points: 40, 60 or 80 ms after the J point (HR independent); 60/80 HR dependent Respiration (ECG) Measurement Range: 4 – 199 rpm Resolution: 1 rpm Accuracy: 4 – 150 rpm: ±2 rpm or ±2%, whichever is greater 155 – 199 rpm: ±4% Sensing Lead: II or I (default: lead II) Sweep Speed: 3.125, 6.25, 12.5, 25 mm/sec Respiration (CO2) Measurement Range: 0 – 150 rpm Resolution: 1 rpm Accuracy: 0 – 70 rpm: ±1 rpm | 71 – 120 rpm: ±2 bpm | 121 – 150 rpm: ±3 bpm Non-Invasive Blood Pressure Measurement Method: Oscillometric Measurement Modes: Manual, Interval, Stat Static Pressure Range: 0 – 300 mmHg Accuracy: ± 3 mmHg Invasive Blood Pressure Resolution: 1 mmHg Accuracy: ±2 mmHg or 2% of the signal value, whichever is greater (excluding transducer) Zero Offset Range: ±120 mmHg Zero Accuracy: ±1 mmHg Excitation: 5 Volts DC, ±2% Frequency Response: 8 Hz ±1 Hz , 12 Hz ±1 Hz, 16 Hz ±1 Hz, (-3 db Point) Pulse Oximetry - Masimo SET SpO2 Resolution: 1% Accuracy: Adult: ±2% with no motion | ±3% during motion conditions, with motion resistant sensors Pediatric: ±2% with no motion | ±3% during motion conditions, with motion resistant sensors Neonate: ±3% with no motion | ±3% during motion conditions, with motion resistant sensors Pulse Oximetry - Nellcor OxiMax SpO2 Resolution: 1% Accuracy: 70–100% ±2% for sensors: MAX-A, MAX-AL, MAX–P, MAX-I, MAX-N (Adult), MAX-N (Neonate) | 70–100% ±2.5% for sensors: OxiCliq A, OxiCliq P, OxiCliq I, OxiCliq N (Adult), OxiCliq N (Neonate) | 70–100% ±3% for sensors: DS-100A, D-YS ( Infant to Adult), OXI-A/N (Adult), OXI-P/I | 70–100% ±3.5% for sensors: D-YS with D-YSE Ear Clip, D-YS with D-YSPD Spot Clip | 70–100% ±4% for sensors: D-YS (Neonate), OXI-A/N (Neonate) Temperature Unit of Measure: Selectable °C or °F Measurement Range: 15 – 45°C, inclusive | 59 – 113°F, inclusive Resolution: 0.1°C, 0.1°F Accuracy: ±0.1°C (15 – 45°C), exclusive of probe errors | ±0.2°F (59 – 113°F), exclusive of probe errors CO2 Microstream® Module Measurement Range: 0 – 99 mmHg, inclusive (at sea level) Accuracy: 0 – 38 mmHg: ±2 mmHg | 39 – 99 mmHg: ±(5% of reading + 0.08% for every 1 mmHg above 38 mmHg) *Accuracy applies for breath rates up to 80 bpm. For breath rates above 80 bpm, accuracy is 4 mmHg or ±12% of reading, whichever is greater, for EtCO2 values exceeding 18 mmHg. Flow Rate: 50 ml/min -7.5 +15 ml/min Environmental Conditions Storage/Transport Temperature: -20 – 60°C (-4 – 140°F) Storage/Transport Humidity: 10 – 95%, non-condensing Storage/Transport Altitude: 1060 – 570 hPa Operating Temperature: 5 – 40°C (41 – 104°F) Operating Humidity: 15 – 95%, non-condensing Operating Altitude: 1060 – 700 hPa Electrical Ratings Battery Type: Lithium Ion Number of Batteries: 3 Battery Voltage: 11.1 V Battery Capacity: 4800 mAh Battery Runtime: 4 hours with three fully charged batteries while monitoring 6-lead ECG, Respiration, Masimo SpO2, 2 IBPs, CO2, Temperature and 1 NIBP and print strip every 15 minutes Battery Recharge Time: 4 hrs maximum
More you might like
Related
Mindray V12 Battery
Related
Mindray V12 Bedside Patient Monitor
Related
Mindray V12 Bedside Patient Monitor
Related