This is a compact vacuum liquid electrolyte injection system for large pouch cell (Max. L370*W360*T12mm). The device with KF40 feedthrough can be used inside the Ar gas glovebox..SPECIFICATIONS: Advanced Features Vacuum liquid electrolyte injection for large pouch cell with the programable setting via the touchscreen controller. Pouch cell vacuum sealing, electrolyte injection, vacuum standing three-in-one design It could be used either in or outside of the glove box Electrolyte injection speed adjustable The electrolyte filler with a speed control console and injection pump for the high-precision dispensing is integrated into the system Electrolyte injection could be done under different vacuum levels in order to achieve a better electrode immersion Compact & desktop; One unit with PLC control Input Power Either AC110 V or AC208-240 V, 50/60 Hz, single phase Power: 1.4 KW Working Gas 0.5~0.8 Mpa high purity compressive inert gas (Ar is preferred) is required for driving the pneumatic system in the glove box Continues dry inert gas purging for the working chamber is required to maintain a dry atmosphere for electrolyte injection and diffusion Air compressors and fitting are required if used in the dry room, but not included. Attention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. Click here to learn the installation of a gas regulator Electrolyte Dispenser A peristaltic pump is used to precisely transfer electrolyte to large pouch cell; Injection Accuracy: 1% During the electrolyte injection and vacuum standing under the vacuum, liquid electrolytes would be vaporized. Please consider refilling the electrolyte if necessary Electrolyte filling volume and injection rate adjustable via touch screen PLC control Large Pouch Cell Size Pouch cells: Max. L 370 mm * W 360 mm * T 12 mm Control Panel A touch screen panel was used to set parameters of vacuum level, inert gas filling, electrolyte injection amount, sealing temperature, and time. Vacuum Degassing: Vacuum range: -95 ~ 0 kPa adjustable Dwell Time: 0~99 seconds adjustable Inert gas filling: Max. pressure: 110 Kpa max. adjustable Dwell Time: 0~99 seconds adjustable Sealing Temperature and time: Two digital temperature controllers on the front panel provide independent control for the left and right heating dies. Temperature range: 25 ~ 220 ℃ adjustable (accuracy ± 3 ℃) Recommended sealing temperature: 180~190 ℃ Sealing time: 0 ~ 99 seconds adjustable (5 ~ 6 seconds is recommended) Electrolyte injection: 0.3 ml - 100 ml programmable under normal atmosphere Injecting under vacuum or inert gas selectable Pouch Cell Sealing Die Sealing width: 2-10 mm (6 mm is the standard one) Sealing accuracy: ~0.03 mm L: 80-370 mm; L1