Oval Gear Flow Meters -MX Positive Displacement Flow Meters | Macnaught
Macnaught MX Overview Macnaught MX Oval Gear Flow Meters are Industrial Grade Positive Displacement Flow Meter devices. Our MX Meters provide true volumetric measurement of liquid thru the meter – not of scale, but actual flow measurement. MX Meter bodies are machined of solid billet, our Rotor shafts are hardened alloy and our Rotor design is unmatched for accuracy and reliability. Our MX PD Meters are for clean fluids, only – no gases or solids-laden liquids. ALL MX METERS PROVIDE A STANDARD .5% ACCURACY with .03% Repeatability of Flow ¼” thru 4” in sizing with .13 GPH to 320+ GPM in Flow Ranges Designed for Precise Volumetric Clean Process Fluid Measurement No Flow Conditioning – put the meter where you need it Large Stock of Meter and Display Inventory including Hazard Classification Meters Immediate response to Flow Meter Inquires Receive an Immediate Flow Meter Proposal or Call our Meter Hotline - (813) 896-2710 METER RFQ FORM Fluid Categories Well Suited for MX Oval Gear Flow Meters Fuels • Oils • Solvents • DEF/ADBLUE • Greases • Lubricants • Fuel Additives • Glycols Polyols • Isocyanates • Asphalt Emulsions • Sealers • Epoxies • Adhesives • DI Water General Water • Acids • Bases • Inks • Chemical Additives • All Clean Process Fluids MX Meter Case Studies > Rail Car Fluid Flow Measurement > Agriculture Chemical Flow Meter > Marine Vessel Fuel Measurement Applications Well Suited for Macnaught Oval Gear Flow Meters Bio Diesel Blending & Production Agriculture Chemical Blending & Dispensing Diesel Fuel Additive Blending Ink Blending Fuel Measurement – Basic Solvent Manufacturing, Blending, Dispensing Fuel Measurement – Advanced Paint & Coating Manufacturing Ethanol Blends Glycols Process Measurement Heating Oil Measurement Sealants & Adhesive Manufacturing Boiler Fuel Measurement Epoxy / Glue Production Bunker & Vessel Fuel Measurement Polymer Production & Measurement Lubricant Blending & Dispensing High Viscosity Fluid Measurement Hydraulic Fluid Measurement DI and General Water Loop Measurement Test Stands Additive Injection & Blending Polyurethane Foam Ratio Blending Acids & Bases Measurement Principle of Operation Principle of Operation The measuring element of an oval gear meter consists of two high-precision splined oval-shaped gears (Rotors). The gears are driven by the flow of the media and “mesh” together. In the presence of flow, exact known defined volumes of fluid are swept through the meter per each rotor rotation. As flow increases, so does the rotational speed of the Rotors. The number of revolutions is a precise highly accurate measure of the fluid that has passed through the meter. Regardless of viscosity, pressure, or temperature. Each “active” Rotor rotation creates a pulse and is detected by a sensor. Each meter is individually calibrated per ISO 17025 standards to .5% accuracy METER FLOW MX Quick Specs MX Meter Specifications Model Size Flow Range MaxPressure Max TempPPS Rotors Max Temp Peek /SS Rotors *Remote display only MX06 ¼” .13-26 GPH 1,000 PSI 176F 248F SS Only MX09 ¼” 4-132 GPH 1,000 PSI 176F 248F SS Only MX12 ½” .5-8 GPM 2,000 PSI 176F 248F SS Only MX19 ¾” .8-21 GPM 2,000 PSI 176F 248F SS or PEEK MX25 1” 1.6-32 GPM 2,000 PSI 176F 248F SS or PEEK MX40 1.5” 2.6-66 GPM 1,500 PSI 176F 248F SS or PEEK MX50 2” 4-200 GPM 1,200 PSI 176F 248F SS or PEEK MX75 3” 5-194 GPM 175 PSI 248F 248F AL Only MX100 4” 31-317 GPM 175 PSI 248F 248F AL Only Notes: Contact Macnaught USA for a Detailed Applications Review and quick response Meter Proposal Call our Meter Hotline ( 813) 896-2710 or use the RFQ Form Link Below METER RFQ FORM Materials Of Construction ¼” thru 2”. All Bodies are Machined from Solid Billet Block. Standard connections are FNPT, numerous connections options available. Standard Pulser is 1 Reed x 1 Hall with 1 Meter of Flying Lead Cable. Numerous Pulser Options are available. Numerous Display Options are available. All Integral Displays are limited to 176F F Series – commonly used for all Fuels, Oils, Greases, Lubricants, all other clean process fluids to 176F F = FNPT Connections / Anodized Aluminum body / PPS Rotors / Viton Body Seal S Series – commonly used for Fuels, Oils, some Solvents, all other clean process fluids up to 248F S = FNPT Connections / Anodized Aluminum Body / SS or PEEK Rotors / FEP Body Seal P Series – commonly used for all above, most Solvents, all other clean process fluids up to 248F P = FNPT Connections / 316SS Body / PPS or PEEK or SS Rotors / FEP Body Seal 302F Maximum High Temp Sensor is available for all sizes. Contact Macnaught USA for Details Higher Pressure Ranges are available in ¼” ( 8000 PSI ) and ½” ( 3,000 PSI ) M Series Models – contact Macnaught USA for Details PPS Body and Rotor ( CR Series ) all plastic Meters available in both ¼” and 1” sizes - contact Macnaught USA for Details MX75 ( 3” ) and MX100 ( 4” ) Meters are cast Aluminum only with Aluminum Rotors only. Viton or FEP Body Seal. Limited pressure range of 175 PSI MX Downloads Commonly Used MX Meter and Display Downloads MX Meter Instruction Manual > Download PDF Review this Manual for Installation Guidelines, Pulse Options, Wiring Instructions, Meter and Meter Part Numbering. PR Integral or Remote Mount Display with Rate & Total Only – no outputs > Download PDF Our PR Display is battery-powered ( 3 year life, common replacement type ) and offers Rate and total only. Total is resettable and non-resettable. Integral Mount is limited to 176F maximum temperature. PRA Integral or Remote Mount Display with Rate and Total with 4-20mA, Pulse and Flow Alarm ( Hi-Low ) outputs > Download PDF Analog output requires loop-power. Pulse output / alarms require 9-30 VDC. Integral Mount is limited to 176F maximum temperature. B-Smart Remote Display accepts all Macnaught Pulse Outputs > Data Sheet Download PDF B-Smart Remote Display > Instruction Manual PDF No external power required for Rate & Total Only. Analog / Pulse Output. Analog loop-powered pulse requires voltage. Numerous engineering value options including lb, kg, ton PRM Integral of Remote Mount Display 4-20mA only – no rate or total values > Download PDF External loop power required. Integral Mount is limited to 176F maximum temperature. Note: Additional specific use displays are available. Pulser Output Options > Download PDF Includes wiring and specifications for Reed x Reed, Hall x Hall, High Resolution ( Double Pulse ), Industrial Pulse Cap and DIN Pulse Module METER RFQ FORM MX Video Overview