LEM PCM 5-PR/SP2, Pointsenz Railway Bipolar DC Current Sensor, 5 Amp Input, Bipolar 4-20mA Output, With 2M cable Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 2M flying leads Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 5-PR/SP2 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 5 Amp Measuring Range +/- 10 Amp Overload Capacity (Ampere Turns) 15000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style Switchcraft EN3L4M connector with 2M Flying Leads Unit Weight 120g Factory Pack Qty 4 Datasheet Product Datasheet Application Notes FAQ