Radium & Uranium Water Filtration System
:root { --crystal-quest-blue: #171796; --midnight-ocean: #0C0C4A; } .control-head-section { padding: 1em; /* border: 1px solid red; */ display: flex; flex-direction: row; flex-wrap : wrap; margin: 0 auto; } .control-head-block { border: 1px solid #D9D9D9; margin: 0 auto 1em; display: flex; flex-direction: column; align-items: center; width: 325px; } .block-content { display: none; } .block-content h3 { margin-bottom: 0.5em; } .img-container { padding: 1em; text-align: center; width: 300px; } .control-head-block img { width: 200px; } .desktop-divider { display: none; } .gpm-label { /* border: 1px solid orange; */ font-weight: 700; color: #171796; text-align: center; /* margin: 0 auto 1em 2em; */ } .gpm-label span { margin-left: 1em; padding: .25em 1em; background-color: #171796; color: white; border-radius: 10px; } .block-content-details { width: 90%; border-top: 1px solid #D9D9D9; padding: 1em; line-height: 1.5; /* max-width: 350px; */ /* border: 1px solid green; */ } .block-content-summary { /* border: 1px solid #171796; */ color: #171796; padding: 1em; font-weight: 700; cursor: pointer; } .block-content-summary::marker { /* color: red; */ font-size: 1.25em; } .block-content ul { padding: 0 1em; text-transform: capitalize; margin-top: 0; } /* SPECIFCATIONS SECTION */ .specs-section { display: flex; flex-direction: column; text-align: center; } .specs-content { display: flex; gap: 60px; flex-direction: row; align-items: center; justify-content: space-between; } /* STYLING FOR SPEC TABLES */ .spec-table { width: 100%; border-collapse: collapse; text-align: center; margin-bottom: 1em; border-radius: 15px; overflow: hidden; box-shadow: 0 4px 8px rgba(227, 229, 230, 0.5); color: #93918D; } .spec-table th { background-color: rgb(23, 23, 150); color: white; padding: 1em 0; border: none !important; /** Remove Shopify default borders */ text-align: center !important; /** Remove Shopify default text alignment */ } .spec-table tr:nth-child(even) { background-color: #ebebeb; } .table-header-link { text-decoration: none; color: white; } .spec-table td { padding: 1em; border: none !important; /** Remove Shopify default borders */ text-align: center !important; /** Remove Shopify default text alignment */ } .spec-table td:first-child { color: var(--midnight-ocean); font-weight: 700; } .spec-table tr:first-child { border-radius: 20px 20px 0 0; } .spec-table tr a { text-decoration: none; color: var(--midnight-ocean); } /* laptop size and up */ @media (min-width: 768px) { .control-head-section { flex-direction: column; } .control-head-block { width: 90%; flex-direction: row; align-items: center; justify-content: space-around; } .block-content-details { display: none; } .block-content { display: block; padding: 2em 2em; /* border-left: 1px solid #D9D9D9; */ font-size: .9em; width: 55%; } .block-content-title { color: #171796; font-weight: 900; } .img-container img { width: 100%; } .desktop-divider { display: block; width: 1px; height: 250px; border-left:1px solid #D9D9D9; } .gpm-label { text-align: left; margin: 0 auto 1em 2em; } } /* laptop size and below */ @media (max-width: 768px) { .spec-table thead tr { font-size: 13px; } .spec-table tbody tr { font-size: 11px; } } Remove Radium and Uranium from Your Drinking Water Radium and uranium are naturally occurring radioactive elements that can enter groundwater supplies through the erosion of bedrock and soil, particularly in areas with high natural deposits. These contaminants are not detectable by taste, smell, or sight, making their presence in drinking water especially concerning. Like many hazardous substances, radium and uranium can pose serious health risks even at low concentrations that do not affect the water’s appearance or flavor. Radium can dissolve into groundwater as it moves through certain types of rock formations, while uranium often enters water sources through natural leaching or human activities such as mining or industrial waste discharge. Both elements are classified as radioactive and can increase the risk of cancer and kidney damage when consumed over time. The EPA has set maximum contaminant levels (MCLs) for these substances—5 picocuries per liter (pCi/L) for combined radium-226 and radium-228, and 30 micrograms per liter (µg/L) for uranium—to help protect public health. This filtration system is specifically engineered to target and reduce radium and uranium levels in water, providing a reliable solution for households and communities with naturally high concentrations or potential contamination from industrial sources. Additional Product Options 12 GPM UV Water Sterilizer: Specifically designed to meet the demanding microorganism control concern. These microorganisms can range from bacteria and viruses to algae and protozoa. A major advantage of UV treatment is that it is capable of disinfecting water faster than chlorine without cumbersome retention tanks and harmful chemicals to your drinking water. Leak Detector Valve: Used to detect a water leak within a water filter system and shuts down the water supply to prevent flooding. Vacuum Breaker: Recommended to be installed inline ahead of water filter systems as a precaution against the rare occurrence of negative pressure (a vacuum) in the water line which can cause damage to the filter tanks and housings. Metered Valve: The systems come standard with a timer valve which runs the backwashing schedule on a set number of days. (For example, every 7 days). The metered valve will run the backwashing based on a set number of gallons. (For example, 3,000 gallons). Oxidation System: Utilizes ozone for efficient water oxidation, improving water quality. Important to Know Pinholes or rust may occur on stainless steel tanks in environments with high humidity, when salt is present or if condensation remains on tank without being routinely wiped down. If your system will be exposed to one of these factors or you are unable to perform the needed maintenance, we recommend a fiberglass tank. *If you are interested in our available add-ons, please call to have them added to your system. **Please speak with a product specialist to determine if dosing or regeneration is needed for your water.** Compatible Valves: GPM:15 2510 Automatic Control Head Elevate your water treatment system with the cutting-edge 2510 Automatic Control Head, engineered for unparalleled precision and adaptability. This advanced control head is designed to meet the diverse needs of both filtration and water softening systems, offering two distinct operational modes to suit your specific requirements. Features: Electromechanical Timer valves 3/5” control valve Standard 1.9" distributor pilot high service flow rate of 19 GPM backwash capacity of 17 GPM valves use all brass material engineered for commercial & industrial use Add-Ons: NXT Display Controller Meter Valves 2510 Automatic Control Head Elevate your water treatment system with the cutting-edge 2510 Automatic Control Head, engineered for unparalleled precision and adaptability. This advanced control head is designed to meet the diverse needs of both filtration and water softening systems, offering two distinct operational modes to suit your specific requirements. Features: Electromechanical Timer valves 3/5” control valve Standard 1.9" distributor pilot high service flow rate of 19 GPM backwash capacity of 17 GPM valves use all brass material engineered for commercial & industrial use Add-Ons: NXT Display Controller Meter Valves GPM:20 - 35 2850 Automatic Control Head This advanced control head is designed to meet the diverse needs of both filtration and water softening systems, offering two distinct operational modes to suit your specific requirements. Features: Electromechanical Timer valves 1 1/2” control valve Standard 1.9" distributor pilot high service flow rate of 60 GPM backwash capacity of 47 GPM valves use all brass material Fully adjustable 5-cycle control engineered for commercial & industrial use Add-Ons: NXT Display Controller XT Display Controller Meter Valves 2850 Automatic Control Head This advanced control head is designed to meet the diverse needs of both filtration and water softening systems, offering two distinct operational modes to suit your specific requirements. Features: Electromechanical Timer valves 1 1/2” control valve Standard 1.9" distributor pilot high service flow rate of 60 GPM backwash capacity of 47 GPM valves use all brass material Fully adjustable 5-cycle control engineered for commercial & industrial use Add-Ons: NXT Display Controller XT Display Controller Meter Valves GPM:60 - 75 2900 Automatic Control Head Elevate your water treatment setup with the 2900 Automatic Control Head, designed to redefine performance standards in commercial, industrial, and hot water applications. This advanced control head integrates superior technology and robust construction to deliver unmatched efficiency and reliability. Features: Electromechanical Timer valves 2” control valve high service flow rate of 106 GPM backwash capacity of 36 GPM valves use all brass material self adjusting backwash controller engineered for commercial & industrial use Add-Ons: NXT Display Controller XT Display Controller Meter Valves 2900 Automatic Control Head Elevate your water treatment setup with the 2900 Automatic Control Head, designed to redefine performance standards in commercial, industrial, and hot water applications. This advanced control head integrates superior technology and robust construction to deliver unmatched efficiency and reliability. Features: Electromechanical Timer valves 2” control valve high service flow rate of 106 GPM backwash capacity of 36 GPM valves use all brass material self adjusting backwash controller engineered for commercial & industrial use Add-Ons: NXT Display Controller XT Display Controller Meter Valves GPM:200 - 390 3900 Control Head This robust and versatile control valve is designed to provide superior performance for both filtration and softening applications. With its advanced timer and metering options, the Vtrol V39 ensures precise control and efficient water management. Features: NXT Display Controller 3" BSP female connections and 6" tank adaptersr valves use all brass material Supports both downflow (DF) and upflow (UF) regeneration engineered for commercial & industrial use Add-Ons: NXT Display Controller Meter Valves 3900 Automatic Control Head This robust and versatile control valve is designed to provide superior performance for both filtration and softening applications. With its advanced timer and metering options, the Vtrol V39 ensures precise control and efficient water management. Features: NXT Display Controller 3" BSP female connections and 6" tank adaptersr valves use all brass material Supports both downflow (DF) and upflow (UF) regeneration engineered for commercial & industrial use Add-Ons: NXT Display Controller Meter Valves GPM:15 - 75 Manual Backwash Control Features: easy operation Manual Filter Valve, Top Mount, 1" In/Out, 1" Female Drain, 1.05" OD Riser, 2.5" 8-NPSM Connection Manual Filter Valve, Top Mount, 2" In/Out, 1.5" Female Drain, 1.5" OD Riser, 4" 8-UN Connection Manual Backwash Control This robust and versatile control valve is designed to provide superior performance for both filtration and softening applications. With its advanced timer and metering options, the Vtrol V39 ensures precise control and efficient water management. Features: NXT Display Controller 3" BSP female connections and 6" tank adaptersr valves use all brass material Supports both downflow (DF) and upflow (UF) regeneration engineered for commercial & industrial use Add-Ons: NXT Display Controller Meter Valves GPM:15 - 75 Manual Upflow Head Features: No electricity and no back wash easy operation can be either up or down flow simply by plumbing it backwards Tank Head, UPVC, 2.5"-8NPSM Opening (1" NPT IN/OUT, 1" NPT Center Riser) Tank Head, UPVC, 4"-8UN Opening (2" NPT IN/OUT, 1.5" NPT Center Riser) 3900 Automatic Control Head This robust and versatile control valve is designed to provide superior performance for both filtration and softening applications. With its advanced timer and metering options, the Vtrol V39 ensures precise control and efficient water management. Features: NXT Display Controller 3" BSP female connections and 6" tank adaptersr valves use all brass material Supports both downflow (DF) and upflow (UF) regeneration engineered for commercial & industrial use Add-Ons: NXT Display Controller Meter Valves ### Specification CQE-CO-RU116 CQE-CO-RU119 CQE-CO-RU122 CQE-CO-RU125 CQE-CO-RU128 CQE-CO-RU131 CQE-CO-RU133 CQE-CO-RU134 CQE-CO-RU135 Service Flow Rate GPM 15 20 35 60 75 185 200 245 390 Peak Flow GPM 22 41 60 95 140 250 270 280 450 Backwash Flow GPM 5 7 12 15 25 35 50 65 75 Pipe Size 1" 1.5" 1.5" 2" 2" 2" / 3" 3" 3" 3" Electronic Control Valve 2510 2850 2850 2900 2900 3150 / 3900 3900 3900 3900 Radium and Cadmium Removal Media 3 ft³ 4 ft³ 7 ft³ 10 ft³ 15 ft³ 20 ft³ 30 ft³ 40 ft³ 60 ft³ PSI Range 35-60 35-60 35-60 35-60 35-60 35-60 35-60 35-60 35-60 Mineral Tank Size (in.) 14" x 65" 16" x 65" 21" x 62" 24" x 72" 30" x 72" 36" x 72" 42" x 72" 48" x 72" 63" x 83" Space Required (in.) (D x H) 16" x 75" 18" x 75" 23" x 84" 24" x 95" 32" x 95" 40" x 192" 46" x 192" 52" x 192" 67" x 203" Quartz (lbs.) 30 40 70 100 150 200 300 400 600 ### Filtration Media Information Product Data Sheet Safety Data Sheet MetalX™-Lite MetalX™-Lite Product Data Sheet MetalX™-Lite Safety Data Sheet ERA 6500 & 9500 ERA 6500 & 9500 Product Data Sheet ERA 6500 & 9500 Safety Data Sheet Ion Exchange Ion Exchange Resin Product Data Sheet Ion Exchange Resin Safety Data Sheet ### MetalX™-Lite PDS MetalX™-Lite SDS 2510 Control Head Manual 2850 Control Head Manual 2900 Control Head Manual 3900 Control Head Manual 5600 Control Head Manual General Commercial Tank Manual
More you might like
Related
Radium & Uranium Water Filtration System
Related
Radium & Uranium Water Filtration System
Related
Radium & Uranium Water Filtration System
Related